错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

A Small High-Temperature Rubidium Frequency Standard

  • Yuxi Li,
  • Shiguang Li,
  • Tongmin Yang,
  • Nina Ma,
  • Zhaohua Liu,
  • Weili Wang,
  • Liang Wang

摘要

The rubidium frequency standard is widely used in many fields because of its small size, reliable performance, and economical application. However, the current mainstream commercial rubidium frequency standard has a working temperature range of −45 ℃ to +70 ℃, which cannot meet the long-term use requirements of high temperature environments above +70 ℃.The operating temperature of the physical package of the rubidium frequency standard is improved by changing the parameters such as the type of buffer gas, gas pressure, and type of rubidium filling in the rubidium bulb and rubidium absorption cell. The operating temperature range of the small high-temperature rubidium frequency standard is expanded to −45 ℃ ~ +80 ℃, and the volume is compressed to 100 mm × 100 mm × 25 mm. The test data shows that the frequency stability of the small high-temperature rubidium frequency standard is better than 3E-11/ \(\sqrt{\uptau }\) (τ:1 s ~ 1000 s), the temperature frequency characteristic is better than 5E-9 in the range of −45 ℃ ~ +80 ℃, and it can remain locked at the ambient temperature of +85 ℃.