There is a connecting duct for the transport of the hot and cold primary helium between both components, reactor, and IHX. These components are arranged inside an inner concrete cell, which is positioned in the reactor building and which is dense in normal operation. After depressurization accidents of the primary circuit, the inner cell will be closed by applying a special selfacting closure system to limit the amount of air, that could ingress into the primary system.

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Concept of a VHTR (Very High-Temperature Reactor)

  • Kurt Kugeler,
  • Zuoyi Zhang

摘要

There is a connecting duct for the transport of the hot and cold primary helium between both components, reactor, and IHX. These components are arranged inside an inner concrete cell, which is positioned in the reactor building and which is dense in normal operation. After depressurization accidents of the primary circuit, the inner cell will be closed by applying a special selfacting closure system to limit the amount of air, that could ingress into the primary system.