Operation Optimization of the Cold End System with Dual-Pressure Condenser of 1000 MW Coal-Fired Unit

  • Li Liu,
  • Yan Liu,
  • Guoqing Li,
  • Pan Qin,
  • Diping Zhao,
  • Xiao Chen,
  • Shenglong Zeng

摘要

Taking the cold end system with dual-pressure condenser of a 1000 MW coal-fired unit as the research object, considering real-time parameters during operation, the full working conditions real-time optimization model was established. Based on the historical operation data, the accuracy of the model was verified, the influence of changes in real-time state parameters such as load, circulating water inlet temperature and clean coefficient on the optimization calculation results was analyzed, and the optimal circulating pump operation mode and energy saving potential under calculated working conditions were obtained. The calculation results showed that, 63.44% of the calculation conditions had achieved energy saving effect, and the cumulative income could reach 604.16 MW·h, the optimal operation modes of the circulating water pump were more necessary to reasonably determine Under the working conditions of high load and high inlet water temperature.