The fluxgate sensor is the most widely used sensor in vector magnetic measurement. However, during long-term continuous observation, the fluxgate sensor will produce large measurement errors due to changes in ambient temperature. This paper proposes a temperature calibration method for the fluxgate sensor based on polynomial fitting to address the temperature error of fluxgate sensors. First, the effect of temperature on the performance indicators of the fluxgate sensor was analyzed. Second, according to the existing temperature-magnetic field data, a temperature calibration model of the fluxgate sensor was constructed. And compared it with other temperature calibration method, the result shows that the proposed temperature calibration method is relatively simple and can better achieve real-time calibration for sensor application scenarios. Finally, to verify the effectiveness of the proposed method, numerous laboratory experiments were implemented. The temperature drift was reduced from about 700 nT before calibration to about 1 nT, root mean square error \(RMSE = \mathrm{{ 11}}\mathrm{{.7189}}\) , indicating that the proposed method has a good temperature calibration effect on the data measured by the fluxgate sensor within the variable temperature background.

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Research on Temperature Error Calibration Method of Fluxgate Sensor

  • Ruiping Yang,
  • Jian Ge,
  • Wang Luo,
  • Xiangyun Hu,
  • Jinhua She,
  • Daisuke Chugo,
  • Haobin Dong

摘要

The fluxgate sensor is the most widely used sensor in vector magnetic measurement. However, during long-term continuous observation, the fluxgate sensor will produce large measurement errors due to changes in ambient temperature. This paper proposes a temperature calibration method for the fluxgate sensor based on polynomial fitting to address the temperature error of fluxgate sensors. First, the effect of temperature on the performance indicators of the fluxgate sensor was analyzed. Second, according to the existing temperature-magnetic field data, a temperature calibration model of the fluxgate sensor was constructed. And compared it with other temperature calibration method, the result shows that the proposed temperature calibration method is relatively simple and can better achieve real-time calibration for sensor application scenarios. Finally, to verify the effectiveness of the proposed method, numerous laboratory experiments were implemented. The temperature drift was reduced from about 700 nT before calibration to about 1 nT, root mean square error \(RMSE = \mathrm{{ 11}}\mathrm{{.7189}}\) , indicating that the proposed method has a good temperature calibration effect on the data measured by the fluxgate sensor within the variable temperature background.