This paper presents a current-stress-optimized (CSO) triple phase shift (TPS) modulation strategy for dual active bridge (DAB). The current stress and transmission power of each effective switching mode is expressed by three control variables. The global current stress minimization of TPS is obtained by using Karush-Kuhn-Tucker (KKT) condition. Simulation results verify the effectiveness of the TPS modulation strategy.

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Optimal Phase Shift Control to Minimize Current Stress for Dual Active Bridge Converter

  • Baolong Liu,
  • Kun Wei,
  • Liang Wu,
  • Zhaolong Sun,
  • Yuxin Niu,
  • Zhanghui Chen

摘要

This paper presents a current-stress-optimized (CSO) triple phase shift (TPS) modulation strategy for dual active bridge (DAB). The current stress and transmission power of each effective switching mode is expressed by three control variables. The global current stress minimization of TPS is obtained by using Karush-Kuhn-Tucker (KKT) condition. Simulation results verify the effectiveness of the TPS modulation strategy.