In order to solve the output signal matching problem of broadband voltage transformers, this paper designs a broadband voltage transformation unit based on zero pole feedback, which can achieve input signal inversion and 1:10 arbitrary ratio boosting function. Error analysis and testing are carried out on the broadband voltage transformation unit, and the output errors are respectively 42ppm and 24urad at any ratio of 1:1–1:10 boosting. The voltage transformation unit designed is beneficial for the development of wideband voltage sensors and is of great significance for the measurement of wide dynamic signals in new power systems.

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Development of Wideband Voltage Transformation Unit Based on Zero-Pole Feedback Technology

  • Liu Jian,
  • Liu Junjie,
  • Wang Jian,
  • Yuan Ruiming,
  • Yi Shuhui,
  • Li Ming

摘要

In order to solve the output signal matching problem of broadband voltage transformers, this paper designs a broadband voltage transformation unit based on zero pole feedback, which can achieve input signal inversion and 1:10 arbitrary ratio boosting function. Error analysis and testing are carried out on the broadband voltage transformation unit, and the output errors are respectively 42ppm and 24urad at any ratio of 1:1–1:10 boosting. The voltage transformation unit designed is beneficial for the development of wideband voltage sensors and is of great significance for the measurement of wide dynamic signals in new power systems.