To maintain the high efficiency of air source heat pump (ASHP) under frosting conditions, the periodic defrosting is required. The earlier and later defrosting can both cause a decrease in its average coefficient of performance (COP) throughout the frosting-defrosting process. Accurately predicting the frosting rate and using it for defrosting control is a fundamental method to solve this problem. However, there is still lack of a universal model for predicting the frosting rate. To solve this problem, a mathematical model for variable-frequency ASHP was developed firstly, which can simulate its operating parameters under different conditions. Combining with the enthalpy diagram, a calculation method for the initial frosting rate of ASHPs was proposed. Then, an initial frosting rate prediction model suit for all operating conditions was developed utilizing the calculation results. Results indicate that the developed frosting rate prediction model for ASHPs demonstrates well predictive performance. The deviations between the predicted values and actual values are mainly within ±15%. Besides, the initial frosting rate can characterize the overall frosting degree and be used to predict the total frost mass throughout the frosting process. The maximum relative error between the predicted total frosting mass and the experimental results is 9.25%.

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

A Universal Prediction Model for Initial Frosting Rate of Air Source Heat Pumps Based on the Enthalpy Diagram

  • Wenzhe Wei,
  • Yutao Guo,
  • Zhike Jiang,
  • Xinyu Zhang,
  • Wei Wang,
  • Yuying Sun,
  • Shiquan Wang,
  • Chunxiao Zhang

摘要

To maintain the high efficiency of air source heat pump (ASHP) under frosting conditions, the periodic defrosting is required. The earlier and later defrosting can both cause a decrease in its average coefficient of performance (COP) throughout the frosting-defrosting process. Accurately predicting the frosting rate and using it for defrosting control is a fundamental method to solve this problem. However, there is still lack of a universal model for predicting the frosting rate. To solve this problem, a mathematical model for variable-frequency ASHP was developed firstly, which can simulate its operating parameters under different conditions. Combining with the enthalpy diagram, a calculation method for the initial frosting rate of ASHPs was proposed. Then, an initial frosting rate prediction model suit for all operating conditions was developed utilizing the calculation results. Results indicate that the developed frosting rate prediction model for ASHPs demonstrates well predictive performance. The deviations between the predicted values and actual values are mainly within ±15%. Besides, the initial frosting rate can characterize the overall frosting degree and be used to predict the total frost mass throughout the frosting process. The maximum relative error between the predicted total frosting mass and the experimental results is 9.25%.