Preeclampsia is a major driver of perinatal morbidity in Mexico, yet no robust, non-invasive electrocardiographic biomarker reliably flags affected fetuses. Recently, electrocardiogram (ECG) signal tortuosity has been validated as a non-invasive biomarker capable of distinguishing between healthy and diseased adults. We investigated whether the tortuosity of the non-invasive fetal ECG (NI-FECG) differs between normotensive and pre-eclamptic pregnancies. Five-minute epochs of NI-FECG were obtained from 26 third-trimester singleton pregnancies, classified into normotensive (Control, n = 16) and preeclamptic (Preeclampsia, n = 10) groups. Recordings were acquired using six abdominal leads (C1, C3, C4, C5, C6, C7). Tortuosity was calculated using the Slope Change Code and normalized by sequence length. Comparisons were made between groups (Control vs. Preeclampsia) and across channels (C1–C7) within each group. Tortuosity values conformed to Gaussian distributions across all leads. No intergroup differences were detected (p > 0.05). In the Control group, intrachannel variability was non-significant (ANOVA p = 0.1145). However, the Preeclampsia group showed a near-significant omnibus result (p = 0.0652); LSD testing revealed three significant contrasts: C3 vs C6 (p = 0.0163), C4 vs C6 (p = 0.0339), and C4 vs C7 (p = 0.0433). Although global tortuosity failed to distinguish normotensive from preeclamptic pregnancies, channel-specific deviations confined to the preeclampsia cohort may indicate region-dependent alterations of the fetal cardiac vector. Larger, longitudinal studies employing standardized fetal lead configurations are warranted to determine whether spatial tortuosity patterns can evolve into a practical, low-overhead biomarker of fetal compromise.

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Exploring Tortuosity as a Non-invasive Indicator of Fetal ECG Abnormalities in Preeclamptic Pregnancies

  • José Antonio Vázquez-Monzón,
  • Didier Torres-Guzmán,
  • Eduardo Barbará-Morales,
  • Catalina Miranda-Saucedo,
  • José Javier Reyes-Lagos

摘要

Preeclampsia is a major driver of perinatal morbidity in Mexico, yet no robust, non-invasive electrocardiographic biomarker reliably flags affected fetuses. Recently, electrocardiogram (ECG) signal tortuosity has been validated as a non-invasive biomarker capable of distinguishing between healthy and diseased adults. We investigated whether the tortuosity of the non-invasive fetal ECG (NI-FECG) differs between normotensive and pre-eclamptic pregnancies. Five-minute epochs of NI-FECG were obtained from 26 third-trimester singleton pregnancies, classified into normotensive (Control, n = 16) and preeclamptic (Preeclampsia, n = 10) groups. Recordings were acquired using six abdominal leads (C1, C3, C4, C5, C6, C7). Tortuosity was calculated using the Slope Change Code and normalized by sequence length. Comparisons were made between groups (Control vs. Preeclampsia) and across channels (C1–C7) within each group. Tortuosity values conformed to Gaussian distributions across all leads. No intergroup differences were detected (p > 0.05). In the Control group, intrachannel variability was non-significant (ANOVA p = 0.1145). However, the Preeclampsia group showed a near-significant omnibus result (p = 0.0652); LSD testing revealed three significant contrasts: C3 vs C6 (p = 0.0163), C4 vs C6 (p = 0.0339), and C4 vs C7 (p = 0.0433). Although global tortuosity failed to distinguish normotensive from preeclamptic pregnancies, channel-specific deviations confined to the preeclampsia cohort may indicate region-dependent alterations of the fetal cardiac vector. Larger, longitudinal studies employing standardized fetal lead configurations are warranted to determine whether spatial tortuosity patterns can evolve into a practical, low-overhead biomarker of fetal compromise.