Open Femoral Fracture Treated with Internal Fixation Converted to Circular External Fixation due to Infection
摘要
Seven year old female sustained a Salter-Harris II comminuted distal type IIIA open femoral fracture with associated bone loss. She was treated initially with locking plate internal fixation and converted to a circular external fixator because of an acute infection and loss of fixation.