Acute Correction of Tibial Deformity and Plate Fixation, with Subsequent Lengthening Over Plate

  • Mahmoud A. El-Rosasy

摘要

The use of circular external fixator for gradual correction of distal tibial deformity associated with hypertrophic nonunion has been a successful technique (Saleh and Royston, J Bone Joint Surg Br 78(1):105–109, 1996). Due to inconvenience of the external fixator, a more convenient fixation method could be used in carefully selected cases (McKee et al., J Bone Joint Surg Br 80:360–364, 1998). Provided that the resultant leg length discrepancy after treatment is less than one inch and is acceptable by the patient, then acute correction of the deformity and fixation by a locked compression plate has been successful with gratifying results to both the patient and surgeon (Helfet et al., J Bone Joint Surg Am 74(9):1286–1297, 1992; El-Rosasy and El-Sallakh, Strateg Trauma Limb Reconstr 8(1):31–35, 2013). In this case fixator-assisted correction of a hypertrophic nonunion with deformity was done followed by plate insertion. Staged lengthening over the plate was performed with a monolateral frame. Two examples of integrated fixation techniques (fixator-assisted plating and lengthening over a plate) were combined in the treatment of this patient.