错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Ion Chromatography Method for Simultaneous Determination of Five Anions in Rural Domestic Drinking Water

  • Chen Guojuan,
  • Chen Haiying,
  • Xu Xiaoxin,
  • Wang Xin

摘要

In this study, an ion chromatography method was developed for simultaneous determination of F−, Cl−, NO2−, NO3−, and SO42− in rural domestic drinking water. Through analysis of five standard substances, the measured values were consistent with the standard values. The detection limits of the method ranged from 0.006 to 0.015 mg·L−1, with relative standard deviations (RSD, n = 6) of 2.5–4.3%. The spiked recovery rates in actual samples ranged from 85.0 to 110.0%, meeting the analytical requirements. The method is simple to operate, provides good separation, and offers rapid, accurate, and reproducible analysis results, suitable for various types of water samples and fulfilling the needs of batch water quality testing.