Artificial intelligence systems show promise to aid in the diagnostic pathway of prostate cancer (PC), by supporting radiologists in interpreting magnetic resonance images (MRI) of the prostate. Most MRI-based systems are designed to detect clinically significant PC lesions, with the main objective of preventing over-diagnosis. Typically, these systems involve an automatic prostate segmentation component and a clinically significant PC lesion detection component. In spite of the compound nature of the systems, evaluations are presented assuming a standalone clinically significant PC detection component. That is, they are evaluated in an idealized scenario and under the assumption that a highly accurate prostate segmentation is available at test time. In this work, we aim to evaluate a clinically significant PC lesion detection system accounting for its compound nature. For that purpose, we simulate a realistic deployment scenario and evaluate the effect of two non-ideal and previously validated prostate segmentation modules on the PC detection ability of the compound system. Following, we compare them with an idealized setting, where prostate segmentations are assumed to have no faults. We observe significant differences in the detection ability of the compound system in a realistic scenario and in the presence of the highest-performing prostate segmentation module (DSC: 90.07 ± 0.74), when compared to the idealized one (AUC: 77.97 ± 3.06 and 84.30 ± 4.07, P<.001). Our results depict the relevance of holistic evaluations for PC detection compound systems, where interactions between system components can lead to decreased performance and degradation at deployment time.

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

On Undesired Emergent Behaviors in Compound Prostate Cancer Detection Systems

  • Erlend Sortland Rolfsnes,
  • Philip Thangngat,
  • Trygve Eftestøl,
  • Tobias Nordström,
  • Fredrik Jäderling,
  • Martin Eklund,
  • Alvaro Fernandez-Quilez

摘要

Artificial intelligence systems show promise to aid in the diagnostic pathway of prostate cancer (PC), by supporting radiologists in interpreting magnetic resonance images (MRI) of the prostate. Most MRI-based systems are designed to detect clinically significant PC lesions, with the main objective of preventing over-diagnosis. Typically, these systems involve an automatic prostate segmentation component and a clinically significant PC lesion detection component. In spite of the compound nature of the systems, evaluations are presented assuming a standalone clinically significant PC detection component. That is, they are evaluated in an idealized scenario and under the assumption that a highly accurate prostate segmentation is available at test time. In this work, we aim to evaluate a clinically significant PC lesion detection system accounting for its compound nature. For that purpose, we simulate a realistic deployment scenario and evaluate the effect of two non-ideal and previously validated prostate segmentation modules on the PC detection ability of the compound system. Following, we compare them with an idealized setting, where prostate segmentations are assumed to have no faults. We observe significant differences in the detection ability of the compound system in a realistic scenario and in the presence of the highest-performing prostate segmentation module (DSC: 90.07 ± 0.74), when compared to the idealized one (AUC: 77.97 ± 3.06 and 84.30 ± 4.07, P<.001). Our results depict the relevance of holistic evaluations for PC detection compound systems, where interactions between system components can lead to decreased performance and degradation at deployment time.