错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Experimental Tests on Post-tensioned PC Girders with Grouting Defects Under Different Prestressing Levels: Preliminary Results

  • Daniele Losanno,
  • Simone Galano,
  • Fulvio Parisi,
  • Maria Rosaria Pecce,
  • Edoardo Cosenza

摘要

During last decades, prestressed reinforced concrete (PC) was widely used in the construction of bridge decks. Recent assessments of existing bridges demonstrated how degradation phenomena and construction defects can significantly reduce performance levels of PC elements. In the case of post-tensioned tendons, insufficient grouting of ducts is one of the most common types of defects in existing girders. This paper presents preliminary results of an experimental testing program on 1/5 scale PC bridge girders. The specimens were casted in different configurations including local voids and lacking grout within ducts, while varying the prestress level in the tendons. Experimental outcomes provide useful information for load-bearing capacity assessment of PC girders with defective grout.