Study Objectives: <p>A surrogate metric of obstructive sleep apnea (OSA), sleep apnea–specific hypoxic burden (SASHB), predicts adverse health outcomes associated with the disease and may be useful in assessing therapeutic success. The purpose of this study was to compare outcomes of mandibular protruding oral appliance therapy using apnea-hypopnea index and SASHB in a population with a spectrum of OSA severity.</p> Methods: <p>Individuals with mild, moderate, or severe OSA (n = 152) were treated with mandibular protruding oral appliance therapy in a prospective observational study. Two-night home sleep apnea tests were used to determine baseline and outcome values of apnea-hypopnea index and SASHB.</p> Results: <p>Mean baseline SASHB differed by OSA severity strata, with 0%, 19%, and 94% percent of study participants with mild, moderate, and severe OSA, respectively, having values greater than 60%min/h. At outcome, these values were reduced to 0%, 0%, and 15%, respectively. For the entire population, therapeutic efficacy was 78% using apnea-hypopnea index &lt; 10 events/h as a response criterion and 95% using SASHB &lt; 60%min/h as the criterion.</p> Conclusions: <p>Using a risk-predictive outcome surrogate to assess the efficacy of oral appliance therapy yields a substantially higher estimate of therapeutic efficacy of oral appliance therapy, particularly in patients with severe OSA.</p> <p><b>Clinical Trial Registration:</b> Registry: ClinicalTrials.gov; Name: Feasibility and Predictive Accuracy of an In-Home Computer Controlled Mandibular Positioner in Identifying Favorable Candidates for Oral Appliance Therapy; URL: <a href="https://clinicaltrials.gov/study/NCT03011762">https://clinicaltrials.gov/study/NCT03011762</a>; Identifier: NCT03011762; Registry: ClinicalTrials.gov; Name: Predictive Accuracy of MATRx Plus in Identifying Favorable Candidates for Oral Appliance Therapy; URL: <a href="https://clinicaltrials.gov/study/NCT03217383">https://clinicaltrials.gov/study/NCT03217383</a>; Identifier: NCT03217383; Registry: ClinicalTrials.gov; Name: Validation of a Simplified MATRx Plus; URL: <a href="https://clinicaltrials.gov/study/NCT03812692">https://clinicaltrials.gov/study/NCT03812692</a>; Identifier: NCT03812692.</p> Citation: <p>Mosca EV, Grosse J, Remmers JE. Oral appliance therapy is highly efficacious at reducing sleep apnea–specific hypoxic burden, a metric predictive of cardiovascular morbidity and mortality. <i>J Clin Sleep Med.</i> 2025;21(7):1185–1190.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Oral appliance therapy is highly efficacious at reducing sleep apnea–specific hypoxic burden, a metric predictive of cardiovascular morbidity and mortality

  • Erin V. Mosca,
  • Joshua Grosse,
  • John E. Remmers

摘要

Study Objectives:

A surrogate metric of obstructive sleep apnea (OSA), sleep apnea–specific hypoxic burden (SASHB), predicts adverse health outcomes associated with the disease and may be useful in assessing therapeutic success. The purpose of this study was to compare outcomes of mandibular protruding oral appliance therapy using apnea-hypopnea index and SASHB in a population with a spectrum of OSA severity.

Methods:

Individuals with mild, moderate, or severe OSA (n = 152) were treated with mandibular protruding oral appliance therapy in a prospective observational study. Two-night home sleep apnea tests were used to determine baseline and outcome values of apnea-hypopnea index and SASHB.

Results:

Mean baseline SASHB differed by OSA severity strata, with 0%, 19%, and 94% percent of study participants with mild, moderate, and severe OSA, respectively, having values greater than 60%min/h. At outcome, these values were reduced to 0%, 0%, and 15%, respectively. For the entire population, therapeutic efficacy was 78% using apnea-hypopnea index < 10 events/h as a response criterion and 95% using SASHB < 60%min/h as the criterion.

Conclusions:

Using a risk-predictive outcome surrogate to assess the efficacy of oral appliance therapy yields a substantially higher estimate of therapeutic efficacy of oral appliance therapy, particularly in patients with severe OSA.

Clinical Trial Registration: Registry: ClinicalTrials.gov; Name: Feasibility and Predictive Accuracy of an In-Home Computer Controlled Mandibular Positioner in Identifying Favorable Candidates for Oral Appliance Therapy; URL: https://clinicaltrials.gov/study/NCT03011762; Identifier: NCT03011762; Registry: ClinicalTrials.gov; Name: Predictive Accuracy of MATRx Plus in Identifying Favorable Candidates for Oral Appliance Therapy; URL: https://clinicaltrials.gov/study/NCT03217383; Identifier: NCT03217383; Registry: ClinicalTrials.gov; Name: Validation of a Simplified MATRx Plus; URL: https://clinicaltrials.gov/study/NCT03812692; Identifier: NCT03812692.

Citation:

Mosca EV, Grosse J, Remmers JE. Oral appliance therapy is highly efficacious at reducing sleep apnea–specific hypoxic burden, a metric predictive of cardiovascular morbidity and mortality. J Clin Sleep Med. 2025;21(7):1185–1190.