<p>This recommendation provides a procedure for determining the carbonation depth on the surface of concrete by applying a pH indicator. This includes definitions of carbonation, carbonation depth and carbonation front, as well as descriptions of the different pH indicator solutions that can be used. Recommendations for testing laboratory-prepared specimens and those obtained from concrete structures are also given. This involves guidelines for sample preparation and/or extraction, CO<sub>2</sub> exposure duration, carbonation depth determination and reporting of results. A section on data interpretation is also provided, as carbonation results are used for determining durability of concrete, as well as a criterion for materials selection or for carbon uptake calculations. The new Recommendation CPC-18R1 is intended to supersede the former RILEM recommendation CPC-18, particularly when prescribed as the preferred method for evaluating and reporting carbonation depths.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Recommendation of RILEM TC 281-CCC: RILEM CPC-18R1—guideline for measuring the carbonation depth of hardened concrete using a pH indicator solution

  • Susan A. Bernal,
  • Ueli M. Angst,
  • John L. Provis,
  • Charlotte Thiel,
  • Gregor J. G. Gluth,
  • Yury Villagran-Zaccardi,
  • Nele De Belie

摘要

This recommendation provides a procedure for determining the carbonation depth on the surface of concrete by applying a pH indicator. This includes definitions of carbonation, carbonation depth and carbonation front, as well as descriptions of the different pH indicator solutions that can be used. Recommendations for testing laboratory-prepared specimens and those obtained from concrete structures are also given. This involves guidelines for sample preparation and/or extraction, CO2 exposure duration, carbonation depth determination and reporting of results. A section on data interpretation is also provided, as carbonation results are used for determining durability of concrete, as well as a criterion for materials selection or for carbon uptake calculations. The new Recommendation CPC-18R1 is intended to supersede the former RILEM recommendation CPC-18, particularly when prescribed as the preferred method for evaluating and reporting carbonation depths.