错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Longitudinal Phospho-tau217 Predicts Amyloid Positron Emission Tomography in Asymptomatic Alzheimer’s Disease

  • Robert A. Rissman,
  • M. C. Donohue,
  • O. Langford,
  • R. Raman,
  • S. Abdel-Latif,
  • R. Yaari,
  • K. C. Holdridge,
  • J. R. Sims,
  • D. Molina-Henry,
  • G. Jimenez-Maggiora,
  • K. A. Johnson,
  • P. S. Aisen,
  • R. A. Sperling

摘要

Background

Blood-based AD biomarkers such as plasma P-tau217 are increasingly used in clinical trials as a screening tool.

Objectives

To assess the utility of an electrochemiluminescence (ECL) immunoassay in predicting brain amyloid PET status in cognitively unimpaired individuals.

Setting

Plasma samples collected at baseline, week 12, and week 240 or endpoint originated from the Anti-Amyloid Treatment in Asymptomatic Alzheimer’s Disease (A4) trial and the companion Longitudinal Evaluation of Amyloid Risk and Neurodegeneration (LEARN) study.

Participants

Both A4 and LEARN enrolled eligible cognitively unimpaired persons 65 to 85 years. Individuals with elevated brain amyloid PET levels were eligible for the A4 Study, while those without elevated brain amyloid PET levels were eligible for the LEARN Study.

Intervention

Participants in the A4 Study received intravenous solanezumab (up to 1600 mg) or placebo every 4 weeks. The LEARN Study is an observational study without intervention.

Measurements

Plasma P-tau217 concentration levels from A4 Study participants were measured using an ECL immunoassay. Receiver Operating Characteristic (ROC) curve analysis was performed for each biomarker against amyloid positivity, defined by ≥22 CL and ≥ 33 CL.

Results

Receiver operating characteristic curve (ROC) analysis indicates high diagnostic value of P-tau217 in individuals with amyloid PET ≥ 20 (Area under the ROC (AUROC): 0.87) and ≥ 33 CL (AUROC: 0.89). Repeated testing with the placebo group taken 12 weeks apart (range: 68 to 143 days) and the LEARN participants taken between 1.4 and 1.75 years resulted in a strong positive correlation (Corr. 0.91 (0.90 to 0.92)).

Conclusion

An ECL immunoassay testing plasma P-tau217 accurately predicts amyloid PET positivity in cognitively unimpaired individuals. Our future analyses aim to determine if use of this assay may reduce the screening burden of preclinical individuals into anti-amyloid clinical trials.