Introduction <p>This study aimed to evaluate the accuracy of sentinel lymph node (SLN) biopsy in endometrial cancer across Spain.</p> Methods <p>We conducted a multicenter, retrospective study including patients with stage I–II endometrial cancer (according to International Federation of Gynecology and Obstetrics [FIGO] 2009 criteria, all histologies and grades) who underwent SLN mapping from 2015 to 2022. Indocyanine green (ICG), ICG + technetium-99m (99mTC) and 99mTC with different sites of injections (cervical, uterus, or both) were used. Twenty-nine Spanish centers were enrolled.</p> Results <p>Overall, 1221 patients were analyzed. The median number of resected SLNs was 2 (interquartile range 1–3); 526 (43%) patients received ICG, 332 (27.1%) patients received ICG + 99mTC, and 363 (29.7%) patients received 99mTC alone or with blue dye. The cervical injection was used in 1121 (92%) patients, 60 (5%) patients underwent a uterine injection, and 40 (3%) patients received both. The bilateral mapping rates were 324 (61.6%) for the ICG group, 250 (75.3%) for the ICG + 99mTC group, and 173 (47.7%) for the 99mTC group (<i>p </i>&lt; 0.001). The aortic mapping rate was 18 (3.4%) for the ICG group, 38 (11.5 %) for the ICG + 99mTC group, and 25 (6.9%) for the 99mTC group, respectively (<i>p </i>&lt; 0.001). Empty node packets were only diagnosed in 10 (1.6%) patients in the ICG group (<i>p </i>&lt; 0.001). The sensitivity was 77% for the ICG group, 90% for the ICG + 99mTC group, and 97% for the 99mTC-alone group. The false negative rates were 6 (3.2%) for the ICG group, 2 (1.4%) for the CG + 99mTC group, and 1 (0.5%) for the 99mTC-alone group (<i>p </i>&lt; 0.244).</p> Conclusion <p>We did not find any differences among tracers in terms of accuracy; otherwise, combining 99mTc and ICG achieved the highest overall and bilateral detection rates.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

The MULTISENT Study: A Multicenter Study on the Detection Rate of Sentinel Lymph Node Mapping in Endometrial Cancer Across Spain

  • Natalia R. Gómez-Hidalgo,
  • Silvia Cabrera,
  • Vicente Bebia,
  • Virginia García-Pineda,
  • Pablo Padilla-Iserte,
  • Francesc Fargas Fabregas,
  • Pere Fuste,
  • Paula Alonso,
  • Tomas Gómez Rodriguez,
  • Sergi Fernandez-Gonzalez,
  • Enrique Chacon,
  • Jose Antonio Pérez Alvarez,
  • Reyes Oliver,
  • Antonio Gil-Moreno

摘要

Introduction

This study aimed to evaluate the accuracy of sentinel lymph node (SLN) biopsy in endometrial cancer across Spain.

Methods

We conducted a multicenter, retrospective study including patients with stage I–II endometrial cancer (according to International Federation of Gynecology and Obstetrics [FIGO] 2009 criteria, all histologies and grades) who underwent SLN mapping from 2015 to 2022. Indocyanine green (ICG), ICG + technetium-99m (99mTC) and 99mTC with different sites of injections (cervical, uterus, or both) were used. Twenty-nine Spanish centers were enrolled.

Results

Overall, 1221 patients were analyzed. The median number of resected SLNs was 2 (interquartile range 1–3); 526 (43%) patients received ICG, 332 (27.1%) patients received ICG + 99mTC, and 363 (29.7%) patients received 99mTC alone or with blue dye. The cervical injection was used in 1121 (92%) patients, 60 (5%) patients underwent a uterine injection, and 40 (3%) patients received both. The bilateral mapping rates were 324 (61.6%) for the ICG group, 250 (75.3%) for the ICG + 99mTC group, and 173 (47.7%) for the 99mTC group (p < 0.001). The aortic mapping rate was 18 (3.4%) for the ICG group, 38 (11.5 %) for the ICG + 99mTC group, and 25 (6.9%) for the 99mTC group, respectively (p < 0.001). Empty node packets were only diagnosed in 10 (1.6%) patients in the ICG group (p < 0.001). The sensitivity was 77% for the ICG group, 90% for the ICG + 99mTC group, and 97% for the 99mTC-alone group. The false negative rates were 6 (3.2%) for the ICG group, 2 (1.4%) for the CG + 99mTC group, and 1 (0.5%) for the 99mTC-alone group (p < 0.244).

Conclusion

We did not find any differences among tracers in terms of accuracy; otherwise, combining 99mTc and ICG achieved the highest overall and bilateral detection rates.