Background <p>Drug-coated balloons (DCBs) are widely used in endovascular therapy. While dissection angle and minimum lumen area (MLA) assessed by intravascular ultrasound (IVUS) are known predictors of restenosis, their specific role after DCB angioplasty remains to be fully elucidated. We aimed to identify predictors of restenosis following DCB angioplasty using IVUS findings.</p> Methods <p>We retrospectively enrolled 36 peripheral artery disease patients undergoing DCB angioplasty (Jan 2021–Dec 2023). We evaluated IVUS images post-guidewire and post-DCB at 3-cm intervals, classifying cross-sections by MLA/external elastic membrane area (EEMA) ratio: &gt; 50%, 40%–50%, and &lt; 40%. Primary patency at 1&#xa0;year post-DCB was the primary outcome. Restenosis was objectively determined by a peak systolic velocity ratio of 2.4 on duplex ultrasound, and assessing each cross-sectional images.</p> Results <p>A total of 262 cross-sectional images were acquired and subsequently classified into three distinct groups based on their MLA/EEMA ratio: &gt; 50% (<i>n</i> = 125), 40%–50% (<i>n</i> = 85), and &lt; 40% (<i>n</i> = 52). All guidewires passed through the intraplaque route. Primary patency was significantly higher in the MLA/EEMA &gt; 50% group (94.0% vs. 84.2% vs. 73.3%, log-rank <i>p</i> = 0.005). Specifically, for dissection angles &gt; 60°, patency was markedly better in the MLA/EEMA &gt; 50% group (93.3% vs. 75.0% vs. 55.6%, log-rank <i>p</i> = 0.03). Dissection angles &lt; 60° showed no significant patency differences (93.9% vs. 88.0% vs. 84.2%, log-rank <i>p</i> = 0.14).</p> Conclusions <p>The MLA/EEMA ratio and the degree of dissection angle may be predictors of primary patency following DCB angioplasty. These findings suggest that optimized vessel preparation strategies can effectively mitigate the adverse clinical impact of dissection.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Predictors of restenosis after drug-coated balloon angioplasty for femoropopliteal chronic total occlusion lesions

  • Yuki Shima,
  • Mihoko Sato,
  • Gakuto Bando,
  • Narumi Irie,
  • Kazunori Mushiake,
  • Naoya Inoue,
  • Hiroyuki Tanaka,
  • Kazushige Kadota

摘要

Background

Drug-coated balloons (DCBs) are widely used in endovascular therapy. While dissection angle and minimum lumen area (MLA) assessed by intravascular ultrasound (IVUS) are known predictors of restenosis, their specific role after DCB angioplasty remains to be fully elucidated. We aimed to identify predictors of restenosis following DCB angioplasty using IVUS findings.

Methods

We retrospectively enrolled 36 peripheral artery disease patients undergoing DCB angioplasty (Jan 2021–Dec 2023). We evaluated IVUS images post-guidewire and post-DCB at 3-cm intervals, classifying cross-sections by MLA/external elastic membrane area (EEMA) ratio: > 50%, 40%–50%, and < 40%. Primary patency at 1 year post-DCB was the primary outcome. Restenosis was objectively determined by a peak systolic velocity ratio of 2.4 on duplex ultrasound, and assessing each cross-sectional images.

Results

A total of 262 cross-sectional images were acquired and subsequently classified into three distinct groups based on their MLA/EEMA ratio: > 50% (n = 125), 40%–50% (n = 85), and < 40% (n = 52). All guidewires passed through the intraplaque route. Primary patency was significantly higher in the MLA/EEMA > 50% group (94.0% vs. 84.2% vs. 73.3%, log-rank p = 0.005). Specifically, for dissection angles > 60°, patency was markedly better in the MLA/EEMA > 50% group (93.3% vs. 75.0% vs. 55.6%, log-rank p = 0.03). Dissection angles < 60° showed no significant patency differences (93.9% vs. 88.0% vs. 84.2%, log-rank p = 0.14).

Conclusions

The MLA/EEMA ratio and the degree of dissection angle may be predictors of primary patency following DCB angioplasty. These findings suggest that optimized vessel preparation strategies can effectively mitigate the adverse clinical impact of dissection.