Purpose <p>This study evaluates four large language models’ (LLMs) ability to answer common patient questions preceding transarterial periarticular embolization (TAPE), computed tomography (CT)-guided high-dose-rate (HDR) brachytherapy, and bleomycin electrosclerotherapy (BEST). The goal is to evaluate their potential to enhance clinical workflows and patient comprehension, while also assessing associated risks.</p> Materials and methods <p>Thirty-five TAPE, 34 CT-HDR brachytherapy, and 36 BEST related questions were presented to ChatGPT-4o, DeepSeek-V3, OpenBioLLM-8b, and BioMistral-7b. The LLM-generated responses were independently assessed by two board-certified radiologists. Accuracy was rated on a 5-point Likert scale. Statistics compared LLM performance across question categories for patient-education suitability.</p> Results <p>DeepSeek-V3 attained the highest mean scores for BEST [4.49 (± 0.77)] and CT-HDR [4.24 (± 0.81)] and demonstrated comparable performance to ChatGPT-4o for TAPE-related questions (DeepSeek-V3 [4.20 (± 0.77)] vs. ChatGPT-4o [4.17 (± 0.64)]; <i>p</i> = 1.000). In contrast, OpenBioLLM-8b (BEST 3.51 (± 1.15), CT-HDR 3.32 (± 1.13), TAPE 3.34 (± 1.16)) and BioMistral-7b (BEST 2.92 (± 1.35), CT-HDR 3.03 (± 1.06), TAPE 3.33 (± 1.28)) performed significantly worse than DeepSeek-V3 and ChatGPT-4o across all procedures. Preparation/Planning was the only category without statistically significant differences across all three procedures.</p> Conclusion <p>DeepSeek-V3 and ChatGPT-4o excelled on TAPE, BEST, and CT-HDR brachytherapy questions, indicating potential to enhance patient education in interventional radiology, where complex but minimally invasive procedures often are explained in brief consultations. However, OpenBioLLM-8b and BioMistral-7b exhibited more frequent inaccuracies, suggesting that LLMs cannot replace comprehensive clinical consultations yet. Patient feedback and clinical workflow implementation should validate these findings.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Large language models for patient education prior to interventional radiology procedures: a comparative study

  • Bogdan Levita,
  • Semil Eminovic,
  • Willie Magnus Lüdemann,
  • Dirk Schnapauff,
  • Robin Schmidt,
  • Anna-Maria Haack,
  • Andrea Dell’Orco,
  • Jawed Nawabi,
  • Tobias Penzkofer

摘要

Purpose

This study evaluates four large language models’ (LLMs) ability to answer common patient questions preceding transarterial periarticular embolization (TAPE), computed tomography (CT)-guided high-dose-rate (HDR) brachytherapy, and bleomycin electrosclerotherapy (BEST). The goal is to evaluate their potential to enhance clinical workflows and patient comprehension, while also assessing associated risks.

Materials and methods

Thirty-five TAPE, 34 CT-HDR brachytherapy, and 36 BEST related questions were presented to ChatGPT-4o, DeepSeek-V3, OpenBioLLM-8b, and BioMistral-7b. The LLM-generated responses were independently assessed by two board-certified radiologists. Accuracy was rated on a 5-point Likert scale. Statistics compared LLM performance across question categories for patient-education suitability.

Results

DeepSeek-V3 attained the highest mean scores for BEST [4.49 (± 0.77)] and CT-HDR [4.24 (± 0.81)] and demonstrated comparable performance to ChatGPT-4o for TAPE-related questions (DeepSeek-V3 [4.20 (± 0.77)] vs. ChatGPT-4o [4.17 (± 0.64)]; p = 1.000). In contrast, OpenBioLLM-8b (BEST 3.51 (± 1.15), CT-HDR 3.32 (± 1.13), TAPE 3.34 (± 1.16)) and BioMistral-7b (BEST 2.92 (± 1.35), CT-HDR 3.03 (± 1.06), TAPE 3.33 (± 1.28)) performed significantly worse than DeepSeek-V3 and ChatGPT-4o across all procedures. Preparation/Planning was the only category without statistically significant differences across all three procedures.

Conclusion

DeepSeek-V3 and ChatGPT-4o excelled on TAPE, BEST, and CT-HDR brachytherapy questions, indicating potential to enhance patient education in interventional radiology, where complex but minimally invasive procedures often are explained in brief consultations. However, OpenBioLLM-8b and BioMistral-7b exhibited more frequent inaccuracies, suggesting that LLMs cannot replace comprehensive clinical consultations yet. Patient feedback and clinical workflow implementation should validate these findings.