Background <p>Although mortality is significantly lower with polyethersulfone (PES) membrane compared with polysulfone (PS) membrane in hemodialysis patients, no studies have investigated mortality in patients undergoing online hemodiafiltration (OHDF) according to the types of membrane materials.</p> Methods <p>The retrospective observational study included 411 patients who were receiving OHDF with PES membrane (<i>n</i> = 190), PS membrane (<i>n</i> = 121), and asymmetric triacetate (ATA) membrane (<i>n</i> = 100) at our facilities on 1 July 2017. The 3-year all-cause mortality on PES membrane was compared with PS and ATA membranes using a propensity score matching model and Cox regression analysis with adjustments.</p> Results <p>The mortality was significantly lower in PES membrane compared with PS membrane (<i>P</i> = 0.012, log-rank test; hazard ratio 0.265, 95% confidence interval [CI] 0.087–0.806). However, Cox regression analysis with adjustments revealed no significant difference. On the other hand, the mortality was not significantly different between PES and ATA membranes.</p> Conclusion <p>These findings suggest that the mortality on PES membrane was not significantly different to mortality on PS and ATA membranes in OHDF patients.</p> Trial registration <p>UMIN Clinical Trials Registry, UMIN000050953. Registered 28 April 2023, Prospectively registered, <a href="https://center6.umin.ac.jp/cgi-open-bin/ctr/ctr_view.cgi?recptno=R000058078">https://center6.umin.ac.jp/cgi-open-bin/ctr/ctr_view.cgi?recptno=R000058078</a> and UMIN000051791 Registered 2 August 2023, Prospectively registered, <a href="https://center6.umin.ac.jp/cgi-bin/ctr/ctr_view_reg.cgi?recptno=R000059102">https://center6.umin.ac.jp/cgi-bin/ctr/ctr_view_reg.cgi?recptno=R000059102</a>.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Comparison of mortality on hemodiafilter materials in online hemodiafiltration

  • Kazuyoshi Okada,
  • Hiroyuki Michiwaki,
  • Daisuke Hara,
  • Tomoko Inoue,
  • Manabu Tashiro,
  • Jun Minakuchi

摘要

Background

Although mortality is significantly lower with polyethersulfone (PES) membrane compared with polysulfone (PS) membrane in hemodialysis patients, no studies have investigated mortality in patients undergoing online hemodiafiltration (OHDF) according to the types of membrane materials.

Methods

The retrospective observational study included 411 patients who were receiving OHDF with PES membrane (n = 190), PS membrane (n = 121), and asymmetric triacetate (ATA) membrane (n = 100) at our facilities on 1 July 2017. The 3-year all-cause mortality on PES membrane was compared with PS and ATA membranes using a propensity score matching model and Cox regression analysis with adjustments.

Results

The mortality was significantly lower in PES membrane compared with PS membrane (P = 0.012, log-rank test; hazard ratio 0.265, 95% confidence interval [CI] 0.087–0.806). However, Cox regression analysis with adjustments revealed no significant difference. On the other hand, the mortality was not significantly different between PES and ATA membranes.

Conclusion

These findings suggest that the mortality on PES membrane was not significantly different to mortality on PS and ATA membranes in OHDF patients.

Trial registration

UMIN Clinical Trials Registry, UMIN000050953. Registered 28 April 2023, Prospectively registered, https://center6.umin.ac.jp/cgi-open-bin/ctr/ctr_view.cgi?recptno=R000058078 and UMIN000051791 Registered 2 August 2023, Prospectively registered, https://center6.umin.ac.jp/cgi-bin/ctr/ctr_view_reg.cgi?recptno=R000059102.