Optical coherence tomography detection of retinal neural loss in patients with tuberous sclerosis

  • Paula Basso Dias,
  • Anna Carolina Badotti Linhares,
  • Ana Barbara Dias Lopes Urzedo,
  • Rony Carlos Preti,
  • Leandro Cabral Zacharias,
  • Leonardo Provetti Cunha,
  • Mário Luiz Ribeiro Monteiro,
  • Kenzo Hokazono

摘要

Purpose

Tuberous Sclerosis (TS) is a rare, multisystem genetic disease caused by mutations in the TSC1 and TSC2 genes, leading to abnormalities in cell differentiation and proliferation. This study aimed to evaluate the neural integrity of individuals with TS by using Optical Coherence Tomography (OCT) to examine the peripapillary retinal nerve fiber layer (RNFL) thickness and the macular thickness in patients with TS and to compare with healthy controls.

Methods

Peripapillary and macular OCT scans (Optopol Revo NX SD OCT) were performed on 41 eyes from 22 TS patients, divided into two groups based on the presence of retinal hamartomas, and compared to 20 eyes from a control group. The average peripapillary RNFL thickness was measured for each quadrant. The macular total thickness and ganglion cell layer (GCL) + inner plexiform layer (IPL) thickness were measured based on the Early Treatment Diabetic Retinopathy Study (ETDRS) map. All measurements were then compared between the groups and controls.

Results

The TS group showed significantly reduced RNFL thickness and macular thickness when compared to the control group. Specifically, patients with retinal hamartomas exhibited an even more pronounced thinning of both RNFL and macular thickness.

Conclusions

These findings suggest that TS patients undergo significant changes in retinal neurodevelopment and experience axonal loss. This finding may have significant prognostic utility regarding central nervous system degeneration in TS, particularly among patients with retinal hamartomas. OCT may serve as a valuable tool for assessing axonal structural abnormalities in TS patients.