错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

The clinical efficacy of laser in the nonsurgical treatment of peri-implantitis: a systematic review and meta-analysis

  • Nengwen Huang,
  • Yang Li,
  • Wen Li,
  • Rui Zhao,
  • Yanjing Ou,
  • Jiang Chen,
  • Jinjin Li

摘要

Objective

To systematically assess studies regarding the efficacy of lasers in the nonsurgical treatment of peri-implantitis.

Methods

Electronic and manual searches were performed by two reviewers independently. Randomized controlled trials (RCTs) comparing lasers vs. mechanical debridement or air abrasive on primary outcome (probing depth (PD)) and secondary outcomes (bone loss, bleeding on probing (BOP), clinical attachment level (CAL) and plaque index (PI)) were included. Data extraction and quality assessment were conducted independently. Weighted mean difference (WMD) or standardized mean difference (SMD) and 95% confidence interval (CI) were calculated for continuous outcomes. Publication bias, leave-one-out analysis and GRADE assessment were conducted.

Result

13 eligible publications were included in the review and 12 in the meta-analysis. Solid-state lasers significantly improved in PD (WMD = -0.39, 95% CI (-0.70, -0.09), p = 0.01, moderate-certainty evidence), BOP (SMD =-0.76, 95% CI (-1.23, -0.28), p = 0.002, moderate-certainty evidence) and CAL (WMD =-0.19, 95% CI (-0.39, -0.00), p = 0.05, moderate-certainty evidence), but not in bone loss (WMD = 0.03, 95% CI (-0.13, 0.18), p = 0.74, low-certainty evidence) and PI (SMD =-0.19, 95% CI (-0.42, 0.04), p = 0.11, moderate-certainty evidence) compared with the control group. However, the diode lasers showed no clinical advantages. No publication bias was detected, and leave-one-out analysis confirmed the robustness of findings.

Conclusion

In the nonsurgical treatment of peri-implantitis, solid-state lasers yielded positive influence in term of PD, BOP and CAL, while diode laser provided no beneficial effect. Future well-designed large RCTs are still needed, considering the limitations of included studies.

Clinical relevance

This review aimed to guide clinicians in choosing the appropriate laser for peri-implantitis, enhancing treatment strategies and attaining better outcomes.