Purpose <p>This study aims to develop and validate a dual-time-window (DTW) Patlak plot method that eliminates the need for invasive blood sampling and reduces scan duration. We seek to improve the accuracy of the net influx constant (<InlineEquation ID="IEq1"> <EquationSource Format="TEX">\(K_i\)</EquationSource> </InlineEquation>) estimation, addressing the inaccuracies inherent in traditional DTW and single-time-window methods, which often introduce bias and hinder comparability across different cohorts.</p> Method <p>We developed an unsupervised, multi-branch neural network (NN) to assist in estimating missing data intervals within the DTW protocol, thereby facilitating accurate Patlak analysis. The model fits the mapping from time to the time-activity curve (TAC), generating multiple pseudo input functions (IFs). A correlation coefficient is then computed between each pseudo IF and the voxel-level measured data, extracting statistical information guided by the kinetic process. These correlation scores were used to construct a weighted statistic, serving as the final IF (NNIF). Our approach was validated using both simulation and clinical data, including <InlineEquation ID="IEq2"> <EquationSource Format="TEX">\(^{18}\rm{F}\)</EquationSource> </InlineEquation>-FDG PET scans from 67 lung cancer subjects. Additionally, we compared the performance of our method with other simplified quantification techniques to demonstrate its efficacy in achieving high-quality parametric imaging and reliable quantitative analysis within abbreviated scanning protocols.</p> Result <p>Our proposed method achieved high accuracy in the estimation of IF, with a maximum mean absolute deviation (MAD) of 0.04 in a real patient study. The regressed <InlineEquation ID="IEq3"> <EquationSource Format="TEX">\(K_i\)</EquationSource> </InlineEquation> derived from different DTW scan protocols exhibited good consistency. In simulation studies , the best relative absolute error (RAE) was 0.0302. In real patient study, the optimal average peak signal-to-noise ratio (PSNR) of parametric imaging reached 97.40 dB, while the best average R-squared (<InlineEquation ID="IEq4"> <EquationSource Format="TEX">\(R^{2}\)</EquationSource> </InlineEquation>) in ROI-based quantitative analysis reached 0.991.</p> Conclusions <p>We demonstrate the feasibility of using a weighted statistic, constructed from a multi-branch neural network, to accurately estimate the complete IF. This approach enables the generation of high-quality parametric images with shortened scan protocols, effectively reducing scanning time while ensuring accurate Patlak analysis.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Neural network-aided unsupervised input function estimation for dual-time-window PET Patlak analysis

  • Wenrui Shao,
  • Yarong Zhang,
  • Fen Du,
  • Fangxiao Cheng,
  • Yixin Chen,
  • Xiangxi Meng,
  • Ying Liang,
  • Zhaoheng Xie

摘要

Purpose

This study aims to develop and validate a dual-time-window (DTW) Patlak plot method that eliminates the need for invasive blood sampling and reduces scan duration. We seek to improve the accuracy of the net influx constant ( \(K_i\) ) estimation, addressing the inaccuracies inherent in traditional DTW and single-time-window methods, which often introduce bias and hinder comparability across different cohorts.

Method

We developed an unsupervised, multi-branch neural network (NN) to assist in estimating missing data intervals within the DTW protocol, thereby facilitating accurate Patlak analysis. The model fits the mapping from time to the time-activity curve (TAC), generating multiple pseudo input functions (IFs). A correlation coefficient is then computed between each pseudo IF and the voxel-level measured data, extracting statistical information guided by the kinetic process. These correlation scores were used to construct a weighted statistic, serving as the final IF (NNIF). Our approach was validated using both simulation and clinical data, including \(^{18}\rm{F}\) -FDG PET scans from 67 lung cancer subjects. Additionally, we compared the performance of our method with other simplified quantification techniques to demonstrate its efficacy in achieving high-quality parametric imaging and reliable quantitative analysis within abbreviated scanning protocols.

Result

Our proposed method achieved high accuracy in the estimation of IF, with a maximum mean absolute deviation (MAD) of 0.04 in a real patient study. The regressed \(K_i\) derived from different DTW scan protocols exhibited good consistency. In simulation studies , the best relative absolute error (RAE) was 0.0302. In real patient study, the optimal average peak signal-to-noise ratio (PSNR) of parametric imaging reached 97.40 dB, while the best average R-squared ( \(R^{2}\) ) in ROI-based quantitative analysis reached 0.991.

Conclusions

We demonstrate the feasibility of using a weighted statistic, constructed from a multi-branch neural network, to accurately estimate the complete IF. This approach enables the generation of high-quality parametric images with shortened scan protocols, effectively reducing scanning time while ensuring accurate Patlak analysis.