Background <p>The study aims to maximize clinical scan efficiency for Total-body (TB) <sup>18</sup>F-FDG PET/CT systems by optimizing scan strategies based on theoretical models and clinical experience from a single center.</p> Results <p>This prospective study include two parts. The first part involved simulation experiments using theoretical models to maximize patient throughput and/or minimizing radiotracer activity across four clinical scanning scenarios: fixed working time, predetermined radiotracer activity, integration of various injection activity regimens for a fixed number of patients, and incorporation of dynamic scans into routine static scans within a fixed working time. The optimal scan strategies for these scenarios were then proposed. The second part validated the estimated throughput results through high-throughput tests performed in the real clinical settings with an fixed working time of 8&#xa0;h. Under a fixed working time of 8&#xa0;h, the theoretical patient throughput for full-activity, half-activity, 1/3-activity, and 1/10-activity injection regimens was 60, 48, 43, 30 patients, respectively. The corresponding real clinical throughput achieved was 60, 49, 48, 28 patients. For a total <sup>18</sup>F-FDG activity of 37,000 to 148,000 MBq (1 to 4 Ci), the 1/3-activity injection regimen yielded the highest patient throughput, ranging 52 to 72 patients. Strategically combining various injection activity regimens could reduce radiotracer activity consumption. Additionally, placing full-activity dynamic scans after routine static scans for full-activity, half-activity, and 1/3-activity, and before 1/10 activity, proved to ba more economical strategies.</p> Conclusions <p>Optimized scan strategies for typical clinical scenarios of TB <sup>18</sup>F-FDG PET/CT systems were proposed, which could promote clinical scan efficiency and accommodate diverse clinical requirements. These strategies enable centers to balance throughput and activity efficiency while maintaining diagnostic quality.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Total-body 18F-FDG PET/CT: more choices to promote clinical scanning efficiency

  • Jie Xiao,
  • Shuguang Chen,
  • Xiaoguang Hou,
  • Haojun Yu,
  • Siwei Liu,
  • Taoying Gu,
  • Guobing Liu,
  • Qi Ge,
  • Jingyi Wang,
  • Hongcheng Shi

摘要

Background

The study aims to maximize clinical scan efficiency for Total-body (TB) 18F-FDG PET/CT systems by optimizing scan strategies based on theoretical models and clinical experience from a single center.

Results

This prospective study include two parts. The first part involved simulation experiments using theoretical models to maximize patient throughput and/or minimizing radiotracer activity across four clinical scanning scenarios: fixed working time, predetermined radiotracer activity, integration of various injection activity regimens for a fixed number of patients, and incorporation of dynamic scans into routine static scans within a fixed working time. The optimal scan strategies for these scenarios were then proposed. The second part validated the estimated throughput results through high-throughput tests performed in the real clinical settings with an fixed working time of 8 h. Under a fixed working time of 8 h, the theoretical patient throughput for full-activity, half-activity, 1/3-activity, and 1/10-activity injection regimens was 60, 48, 43, 30 patients, respectively. The corresponding real clinical throughput achieved was 60, 49, 48, 28 patients. For a total 18F-FDG activity of 37,000 to 148,000 MBq (1 to 4 Ci), the 1/3-activity injection regimen yielded the highest patient throughput, ranging 52 to 72 patients. Strategically combining various injection activity regimens could reduce radiotracer activity consumption. Additionally, placing full-activity dynamic scans after routine static scans for full-activity, half-activity, and 1/3-activity, and before 1/10 activity, proved to ba more economical strategies.

Conclusions

Optimized scan strategies for typical clinical scenarios of TB 18F-FDG PET/CT systems were proposed, which could promote clinical scan efficiency and accommodate diverse clinical requirements. These strategies enable centers to balance throughput and activity efficiency while maintaining diagnostic quality.