Objectives <p>To integrate multiple parameters derived from unenhanced spectral CT with 3D-printing technique to accurately evaluate intestinal lesions in patients with Crohn’s disease (CD).</p> Methods <p>Patients with proven CD who underwent preoperative spectral CT and surgery were included. The spectral CT images and histopathological specimens were achieved by employing 3D-printing technique. Diagnostic models were developed utilizing Z-Effective, Electron Density (ED), and Hounsfield unit (HU) values derived from spectral CT, along with spectral curve slopes λ<sub>1</sub> and λ<sub>2</sub>, as well as ΔHU<sub>MonoE</sub>. The area under the receiver operating characteristic curve (AUC) and the influence of inflammation on the efficacy of the models were analyzed.</p> Results <p>The ED and HU at MonoE 50 keV of the spectral CT were determined to exhibit the highest correlation with the fibrosis degree of the diseased intestine. The training dataset yielded an AUC of 0.828 (95% CI: 0.705–0.951). The sensitivity and specificity were calculated to be 77.3% and 82.6%, respectively. The AUC of the validation set was 0.812 (95% CI: 0.676–0.948) with a sensitivity of 63.6% and specificity of 89.7%. Moreover, our model demonstrated enhanced diagnostic accuracy for detecting fibrosis with an AUC value of 0.933 (95% CI: 0.856–1.000), sensitivity of 90.9%, and specificity of 87.0%, after regulating the influence of inflammation.</p> Conclusion <p>The integration of unenhanced multi-parametric spectral CT and 3D-printing technique seems to be able to assess the intestinal fibrosis. Our diagnostic model remains effective in assessing the severity of fibrosis under presence of inflammation.</p> Critical relevance statement <p>Our diagnostic model accurately assessed the degree of intestinal wall fibrosis in Crohn’s disease patients by using unenhanced spectral CT and 3D-printing technique, which could facilitate individualized treatment.</p> Key Points <p><UnorderedList Mark="Bullet"> <ItemContent> <p>Evaluating the extent of Crohn’s disease-related fibrosis is important.</p> </ItemContent> <ItemContent> <p>The combination of 3D-printing technique and multi-parametric spectral CT enhances diagnostic accuracy.</p> </ItemContent> <ItemContent> <p>The developed model using spectral CT allows for the assessment of intestinal fibrosis using multi-parameters.</p> </ItemContent> </UnorderedList></p> Graphical Abstract <p></p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Intestinal fibrosis assessment in Crohn’s disease patient using unenhanced spectral CT combined with 3D-printing technique

  • Qiapeng Huang,
  • Zhihui Chen,
  • Ruonan Zhang,
  • Huasong Cai,
  • Xufeng Yang,
  • Xiaodi Shen,
  • Lili Huang,
  • Xinyue Wang,
  • Qingzhu Zheng,
  • Mingzhe Li,
  • Ziyin Ye,
  • Xubin Liu,
  • Ren Mao,
  • Yangdi Wang,
  • Jinjiang Lin,
  • Zhoulei Li

摘要

Objectives

To integrate multiple parameters derived from unenhanced spectral CT with 3D-printing technique to accurately evaluate intestinal lesions in patients with Crohn’s disease (CD).

Methods

Patients with proven CD who underwent preoperative spectral CT and surgery were included. The spectral CT images and histopathological specimens were achieved by employing 3D-printing technique. Diagnostic models were developed utilizing Z-Effective, Electron Density (ED), and Hounsfield unit (HU) values derived from spectral CT, along with spectral curve slopes λ1 and λ2, as well as ΔHUMonoE. The area under the receiver operating characteristic curve (AUC) and the influence of inflammation on the efficacy of the models were analyzed.

Results

The ED and HU at MonoE 50 keV of the spectral CT were determined to exhibit the highest correlation with the fibrosis degree of the diseased intestine. The training dataset yielded an AUC of 0.828 (95% CI: 0.705–0.951). The sensitivity and specificity were calculated to be 77.3% and 82.6%, respectively. The AUC of the validation set was 0.812 (95% CI: 0.676–0.948) with a sensitivity of 63.6% and specificity of 89.7%. Moreover, our model demonstrated enhanced diagnostic accuracy for detecting fibrosis with an AUC value of 0.933 (95% CI: 0.856–1.000), sensitivity of 90.9%, and specificity of 87.0%, after regulating the influence of inflammation.

Conclusion

The integration of unenhanced multi-parametric spectral CT and 3D-printing technique seems to be able to assess the intestinal fibrosis. Our diagnostic model remains effective in assessing the severity of fibrosis under presence of inflammation.

Critical relevance statement

Our diagnostic model accurately assessed the degree of intestinal wall fibrosis in Crohn’s disease patients by using unenhanced spectral CT and 3D-printing technique, which could facilitate individualized treatment.

Key Points

Evaluating the extent of Crohn’s disease-related fibrosis is important.

The combination of 3D-printing technique and multi-parametric spectral CT enhances diagnostic accuracy.

The developed model using spectral CT allows for the assessment of intestinal fibrosis using multi-parameters.

Graphical Abstract