错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Continuous positive airway pressure is unsafe for radiofrequency ablation of lung cancer under sedation: a randomised controlled trial

  • Enrique Carrero-Cardenal,
  • Ivan Vollmer-Torrubiano,
  • Marta Torres-López,
  • Gloria Martín-Barrera,
  • Georgina Casanovas-Mateu,
  • Francisco-Javier Tercero-Machin,
  • Alfredo Paez-Carpio,
  • Neus Fábregas-Julià,
  • Ricard Valero-Castell

摘要

Objective

To evaluate the safety of a minimum continuous positive airway pressure of 4 cmH2O (CPAP + 4) during computed tomography (CT)-guided radiofrequency ablation (RFA) for lung malignancies under procedural sedation and analgesia (PSA).

Methods

This was a prospective, randomised, single-blind, parallel-group, placebo-controlled trial with an open-label medical device conducted at a single tertiary university hospital in Barcelona, Spain. Forty-six patients over 18 years of age scheduled for CT-guided RFA of a malignant pulmonary tumour under PSA were randomised to receive either CPAP + 4 or a modified mask for placebo CPAP (Sham-CPAP). Exclusion criteria included contraindications for RFA, refusal to participate, inability to understand the procedure or tolerate the CPAP test, lung biopsy just prior to RFA, intercurrent diseases, or previous randomisation for additional pulmonary RFA. Primary outcomes were the percentage of patients reporting at least one serious adverse event (SAE), classification for complications from the Cardiovascular and Interventional Radiological Society of Europe (CIRSE), and Clavien-Dindo classifications for complications, hospital stay, and readmissions. Secondary outcomes included adverse events (AEs), respiratory parameters, airway management, and the local radiological efficacy of pulmonary ablation.

Results

CPAP + 4 prolonged hospital stay (1.5 ± 1.1 vs. 1.0 ± 0 inpatient nights, p = 0.022) and increased the risk of AE post-RFA (odds ratio (95% CI): 4.250 (1.234 to 14.637), p = 0.021 with more pneumothorax cases (n = 5/22, 22.7% vs. n = 0/24, 0%, p = 0.019). Per-protocol analysis revealed more SAEs and CIRSE grade 3 complications in the CPAP + 4 group (23.5% vs. 0%, p = 0.036). No significant differences were found in the effectiveness of oxygenation, ventilation, or pulmonary ablation.

Conclusion

CPAP is unsafe during CT-guided RFA for lung cancer under PSA even at the lowest pressure setting.

Trial registration

ClinicalTrials.Gov, ClinicalTrials.gov ID NCT02117908, Registered 11 April 2014, https://www.clinicaltrials.gov/study/NCT02117908

Critical relevance statement

This study highlights the hazards of continuous positive airway pressure during radiofrequency ablation of lung cancer, even at minimal pressures, deeming it unsafe under procedural sedation and analgesia in pulmonary interventional procedures. Findings provide crucial insights to prioritise patient safety.

Key Points

No prior randomised controlled trials on CPAP safety in percutaneous lung thermo-ablation.

Standardised outcome measures are crucial for radiology research.

CPAP during lung RFA raises hospital stay and the risk of complications.

CPAP is unsafe during CT-guided RFA of lung cancer under procedural sedoanalgesia.

Graphical Abstract