Purpose <p>This study aimed to evaluate the validity and reliability of the Catapult Vector S7 GPS device in measuring total distance in a simulated team sport environment, with the specific goal of providing practical guidance for its application in sports science and practice.</p> Methods <p>Thirty university-level football players performed a Team Sport Simulation Cycle (TSSC), covering a total distance of 1200&#xa0;m. Actual field measurements were used to test the validity of all values. A high-frequency (10&#xa0;Hz) Catapult Vector S7 GPS unit was used to collect movement data, which was compared against reference tape measurements. Statistical analyses included SEM, CV%, SWC, MDC, MAPE%, MAE, RMSE, and Bland-Altman plots.</p> Results <p>The device demonstrated excellent reliability with a CV% of 0.17 and SEM of 2.00. The MDC (5.54) exceeded the SWC (2.19), suggesting high sensitivity in detecting meaningful performance changes. Validity analyses showed minimal error (MAPE% = 0.77; RMSE = 11.55; MAE = 9.40). Bland-Altman analysis indicated low systematic bias and high agreement with reference distances.</p> Conclusions <p>The Catapult Vector S7 GPS unit provides highly reliable and valid measurements of total distance, supporting its application in monitoring athlete workload and performance in team sports. These findings underscore the importance of high-frequency GPS technology in sports science research and practice, significantly contributing to the field.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Validity and reliability of catapult vector S7 GNSS units in distance measurement

  • Mustafa Furkan Ocak,
  • Deniz Şentürk,
  • Zeki Akyildiz

摘要

Purpose

This study aimed to evaluate the validity and reliability of the Catapult Vector S7 GPS device in measuring total distance in a simulated team sport environment, with the specific goal of providing practical guidance for its application in sports science and practice.

Methods

Thirty university-level football players performed a Team Sport Simulation Cycle (TSSC), covering a total distance of 1200 m. Actual field measurements were used to test the validity of all values. A high-frequency (10 Hz) Catapult Vector S7 GPS unit was used to collect movement data, which was compared against reference tape measurements. Statistical analyses included SEM, CV%, SWC, MDC, MAPE%, MAE, RMSE, and Bland-Altman plots.

Results

The device demonstrated excellent reliability with a CV% of 0.17 and SEM of 2.00. The MDC (5.54) exceeded the SWC (2.19), suggesting high sensitivity in detecting meaningful performance changes. Validity analyses showed minimal error (MAPE% = 0.77; RMSE = 11.55; MAE = 9.40). Bland-Altman analysis indicated low systematic bias and high agreement with reference distances.

Conclusions

The Catapult Vector S7 GPS unit provides highly reliable and valid measurements of total distance, supporting its application in monitoring athlete workload and performance in team sports. These findings underscore the importance of high-frequency GPS technology in sports science research and practice, significantly contributing to the field.