Background <p>Automated insulin delivery showed better results than standard insulin therapy, such as MDI. Therefore, we aimed to discuss the efficacy of Control IQ hybrid closed loop (HCL) during the daytime and nighttime for the type 1 diabetic population without restriction in age group or disease severity.</p> Methods <p>We searched PubMed, Scopus, Cochrane Library, Web of Science, and related article citations. We analyzed the time in range (TIR), time below range (TBR), time above range (TAR), HBA1c, and serious adverse events (AEs) to ensure safety and efficacy. We used a random effects model when heterogeneity was present; otherwise, we used a fixed effects model. Data was presented as mean difference and 95% confidence intervals.</p> Results <p>We selected seven randomized controlled trials (RCTs) out of 1339 articles for the analysis. After analysis of pooled studies data, Control IQ showed improvement in TIR 70–180&#xa0;mg/dl 24&#xa0;h data (MD 11.75%, CI 95% (9.54 to 13.97), <i>p</i> = 0.000001) with a similar effect observed in daytime and nighttime. Significant reduction in HbA1c (MD -0.38%, CI 95% (-0.55 to -0.22), <i>p</i> = 0.00001) and 24-hour coefficient variation (CV) measurement (MD -1.42%, CI 95% (-2.22 to -0.61), <i>p</i> = 0.0006) in the Control IQ group compared to the standard therapy group. However, daytime TBR &lt; 70&#xa0;mg/dl did not show significant improvement (MD -0.22%, CI 95% (-0.50 to 0.06), <i>p</i> = 0.12). Regarding safety, Control IQ reduction in DKA was insignificant (OR 1.48 (CI 95%: 0.23–9.55), <i>p</i> = 0.68).</p> Conclusion <p>Control IQ showed better blood glucose control than standard insulin therapy, with some considerations regarding daytime glycemic control that need further assessment.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Daytime and nighttime glycemic control with control-IQ technology vs. standard therapy in type 1 diabetes: a systematic review and meta-analysis with trial sequential analysis and GRADE assessment

  • Rahma Mogahed Rateb,
  • Ammar Salah,
  • Ahmed Kertam,
  • Youssef Adel Youssef Ashmawi,
  • Nourhan Hatem Mahmoud,
  • Eslam Afifi,
  • Ahmed Bayoumi,
  • Salma Allam,
  • Mohamed Saad Rakab

摘要

Background

Automated insulin delivery showed better results than standard insulin therapy, such as MDI. Therefore, we aimed to discuss the efficacy of Control IQ hybrid closed loop (HCL) during the daytime and nighttime for the type 1 diabetic population without restriction in age group or disease severity.

Methods

We searched PubMed, Scopus, Cochrane Library, Web of Science, and related article citations. We analyzed the time in range (TIR), time below range (TBR), time above range (TAR), HBA1c, and serious adverse events (AEs) to ensure safety and efficacy. We used a random effects model when heterogeneity was present; otherwise, we used a fixed effects model. Data was presented as mean difference and 95% confidence intervals.

Results

We selected seven randomized controlled trials (RCTs) out of 1339 articles for the analysis. After analysis of pooled studies data, Control IQ showed improvement in TIR 70–180 mg/dl 24 h data (MD 11.75%, CI 95% (9.54 to 13.97), p = 0.000001) with a similar effect observed in daytime and nighttime. Significant reduction in HbA1c (MD -0.38%, CI 95% (-0.55 to -0.22), p = 0.00001) and 24-hour coefficient variation (CV) measurement (MD -1.42%, CI 95% (-2.22 to -0.61), p = 0.0006) in the Control IQ group compared to the standard therapy group. However, daytime TBR < 70 mg/dl did not show significant improvement (MD -0.22%, CI 95% (-0.50 to 0.06), p = 0.12). Regarding safety, Control IQ reduction in DKA was insignificant (OR 1.48 (CI 95%: 0.23–9.55), p = 0.68).

Conclusion

Control IQ showed better blood glucose control than standard insulin therapy, with some considerations regarding daytime glycemic control that need further assessment.