错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Ultrasound contrast agent assisted ultrasonography guidance percutaneous nephrostomy for non-hydronephrotic kidney

  • Weijie Jiao,
  • Xue Gong,
  • Yuanyuan Sun,
  • Lin Sang,
  • Xiaoying Ding,
  • Ming Yu

摘要

Background

Given the limited success rate and considerable challenges associated with conventional ultrasonography (US) guidance for percutaneous nephrostomy (PCN) in non-hydronephrotic kidneys, this study proposed a solution with ultrasound contrast agent to enhance the success rate and mitigate the difficulties.

Materials and Methods

From January 2017 to August 2023, a total of thirteen patients diagnosed with non-hydronephrotic kidney were included in the study. Following routine ultrasonography examination, no significant dilatation of the renal collecting system was observed. US-guided percutaneous nephrostomy PCN was performed with the assistance of ultrasound contrast agent (UCA). The patients were subsequently monitored to assess the improvement of symptoms and postoperative recovery.

Results

The success rate was found to be 100% for all patients (13/13) and kidneys (20/20). The average volume of UCA solution used was 19 ± 6.7 mL (range, 11–35 mL), while the mean duration of the operation was 18.92 ± 8.96 min (range, 7–36 min). A majority of the patients (12/13) underwent a single puncture procedure. Throughout the follow-up period, no serious complications were observed, and surgery resulted in significant alleviation of symptoms in all patients.

Conclusion

The use of UCA-assisted US guidance PCN has been shown to be effective in achieving urinary diversion and alleviating associated clinical symptoms in non-hydronephrotic kidneys. In comparison to traditional methods, this approach demonstrates a high success rate and safety profile, while also offering a simplified operative procedure. Consequently, it presents a novel method and concept for managing non-hydronephrotic kidneys afflicted by urine leakage.