<p>Entrapment of the ablation catheter in the mitral valve apparatus during transaortic ablation of premature ventricular complexes is a rare complication that usually requires surgical removal. Random rotating and pulling of the catheter exacerbate the extent of the entrapment, causing chest pain and a drop in blood pressure. The catheter can be loosened by changing the direction of the vector at the tip of the catheter, pulling in the reverse direction and rotating. We describe the case of the thought process and catheter maneuvers used to diagnose, loosen, and remove a trapped catheter.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Ablation catheter entrapment in the mitral valve apparatus during ablation of premature ventricular complexes: a case report

  • Fan Wang,
  • Xuelian Song,
  • Litian Liu,
  • Feifei Zhang,
  • Xinning Li,
  • Yi Dang

摘要

Entrapment of the ablation catheter in the mitral valve apparatus during transaortic ablation of premature ventricular complexes is a rare complication that usually requires surgical removal. Random rotating and pulling of the catheter exacerbate the extent of the entrapment, causing chest pain and a drop in blood pressure. The catheter can be loosened by changing the direction of the vector at the tip of the catheter, pulling in the reverse direction and rotating. We describe the case of the thought process and catheter maneuvers used to diagnose, loosen, and remove a trapped catheter.