错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Repair of a fistula between the aorta and right ventricular outflow tract secondary to infective endocarditis of a unicuspid aortic valve and previously repaired ventricular septal defect

  • Rickesh B. Karsan,
  • Katie E. O’Sullivan,
  • Christopher J. Lockhart,
  • Christopher Austin

摘要

Background

Infective endocarditis of the aortic valve can result in a wide range of destructive pathology beyond the valve leaflets and annulus which require careful surgical planning to provide appropriate debridement and reconstruction. Failure to do so can result in a failure of surgical treatment, recurrent infection and cardiac failure with concomitant high morbidity and mortality.

Case report

We describe the case of a 45-year-old male with previous patch repair of a ventricular septal defect, who was diagnosed with sub-acute bacterial endocarditis of the native aortic valve and developed a new fistula from the aorta to the right ventricular outflow tract which. This was managed surgically.

Conclusion

This unique case highlights another spectrum of infective endocarditis with a unique approach to repair and management.