Effect of different loads on facet joint motion during lumbar lateral bending in sitting position

  • Ye Han,
  • Wei Yuan,
  • Shaosong Sun,
  • Bao Ren,
  • Xiong Zhang,
  • Zheng Li,
  • Jun Miao,
  • Xiaodong Wang

摘要

Objective

To study the effect of weight-bearing on lumbar facet joint during lateral bending in sitting position.

Methods

Ten normal healthy people (5 males and 5 females) aged 25–39 years (mean 32 ± 4.29 years) were recruited. CT scanning was used to reconstruct the lumbar spine model, and then dual fluoroscopic image system (DFIS) was used to restore the lumbar facet joint movement in sitting position. Finally, the lumbar facet joint translation distance and rotation angle were measured.

Results

In L3-4 level, the displacement of right facet joint in Y-axis was the smallest at 0.05 ± 0.40 mm, the displacement of 0 kg left facet joint in X-axis was the largest at 1.68 ± 0.85 mm, and the rotation angle was − 0.57 ± 1.43° to 5.66 ± 2.70° at 10 kg; in L4-5 level, the displacement of right facet joint in Y-axis was the smallest at 10 kg, − 0.13 ± 0.91 mm, and the displacement of left facet joint in Z-axis was the largest at − 2.11 ± 0.88 mm, and the rotation angle was 0.21 ± 2.14° to 7.89 ± 2.59° at 10 kg; in L5-S1 level, the displacement of right facet joint in Y-axis was the smallest at 10 kg, − 0.17 ± 1.10 mm, and the displacement of 0 kg left facet joint in X-axis was the largest at 2.19 ± 2.28 mm, and the rotation angle was 0.03 ± 2.02° to 3.98 ± 0.37°.

Conclusion

In sitting position, weight-bearing has certain influence on the displacement of facet joints during lumbar lateral bending movement, and this influence occurs simultaneously in translation and rotation; the left and right facet joints are not symmetrical during lumbar lateral bending movement.