Background /Objectives <p>Preanalytic quality control of surgical specimens is often inadequately managed. This study aimed to share the experience of improving quality through the implementation of a system for preanalytic surgical specimens.</p> Methods <p>After initial workflow mapping and process optimization, a pathology specimen transfer system was piloted and subsequently implemented hospital-wide. Ongoing monitoring and adjustments were made based on established standards and operational needs. Data were analyzed using R Studio software.</p> Results <p>The system reduced errors from 24.82 to 2.40%, including reductions of 86.85% in requisition mistakes, 95.30% in label errors, and 100% in illegible handwriting. From 2020 to 2023, the interval between specimen removal and submission was halved, and delayed fixation decreased from 0.46 to 0.22%.</p> Conclusions <p>The system effectively standardized processes, enhanced efficiency, and reduced errors in preanalytic surgical specimens. Quality improvement was dependent on thorough workflow mapping and optimization, as well as ongoing monitoring and adjustments.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Enhancing preanalytic surgical specimen management: experience of a system implementation initiative

  • Peirong Chen,
  • Weiming Qiu

摘要

Background /Objectives

Preanalytic quality control of surgical specimens is often inadequately managed. This study aimed to share the experience of improving quality through the implementation of a system for preanalytic surgical specimens.

Methods

After initial workflow mapping and process optimization, a pathology specimen transfer system was piloted and subsequently implemented hospital-wide. Ongoing monitoring and adjustments were made based on established standards and operational needs. Data were analyzed using R Studio software.

Results

The system reduced errors from 24.82 to 2.40%, including reductions of 86.85% in requisition mistakes, 95.30% in label errors, and 100% in illegible handwriting. From 2020 to 2023, the interval between specimen removal and submission was halved, and delayed fixation decreased from 0.46 to 0.22%.

Conclusions

The system effectively standardized processes, enhanced efficiency, and reduced errors in preanalytic surgical specimens. Quality improvement was dependent on thorough workflow mapping and optimization, as well as ongoing monitoring and adjustments.