Background <p>Although beneficial for patients through its minimally invasive nature, laparoscopic surgery creates unique training challenges due to limited instrument maneuverability, absence of stereovision, and inadequate real-time feedback. Traditional training models rely on subjective instructor evaluations, which are time-consuming and lack objective error detection. This study evaluates the efficacy of an Automated Error Detection System (AEDS), designed to provide real-time feedback on mistouch error counts, in improving laparoscopic skill acquisition compared to conventional methods.</p> Methods <p>Forty novice participants were recruited and randomized into Group A (AEDS-enhanced training) and Group B (traditional training). Group A underwent a crossover design: 10&#xa0;min of baseline training without AEDS followed by 10&#xa0;min with AEDS. Group B completed 20&#xa0;min of traditional training. The training program encompassed standardized laparoscopic tasks designed to simulate real surgical procedures. Performance metrics, including task completion time and the number of errors made, were recorded for each participant through AEDS. Confidence levels were assessed through self-reported questionnaires. Furthermore, statistical analysis was performed to evaluate the effectiveness of AEDS. A paired t-test was utilized to assess error reductions within the AEDS group, and Bland-Altman analysis was used to analyze the self-estimate error bias. Also, a Wilcoxon signed-rank test evaluated improvements in confidence levels attributable to the system, while a Mann-Whitney U test was conducted to compare performance metrics between the AEDS and traditional training groups.</p> Results <p>Group A demonstrated a 24% reduction in errors post-AEDS (mean: 78.1 to 59.4, <i>p</i> &lt; 0.001), outperforming Group B (mean: 67.4, <i>p</i> &lt; 0.001). Participants significantly underestimated errors without AEDS (mean bias: +9.9 errors). Confidence levels in Group A increased from 2.4 to 3.6, significantly surpassing Group B’s improvement (median: 3) (<i>p</i> &lt; 0.001). Real-time feedback bridged perceptual gaps, enhancing both technical precision and self-assessment accuracy.</p> Conclusion <p>The integration of AEDS into laparoscopic training significantly reduces operational errors, accelerates skill acquisition, and boosts trainee confidence by providing objective feedback. These findings advocate for adopting AEDS in surgical education to standardize training outcomes, mitigate overconfidence, and improve patient safety. Future studies should explore AEDS scalability across advanced procedural modules and diverse trainee cohorts.</p> Clinical trial number <p>Not applicable.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Enhancing laparoscopic surgery training: a comparative study of traditional models and automated error detection system

  • Yitian Luo,
  • Jingjie Wang,
  • Zongting Yan,
  • Jingjing He,
  • Liye Fu,
  • Shenghan Wang,
  • Ying Han,
  • Yaoyu Fu,
  • Xiandi Wang,
  • Kang Li,
  • Rong Yin,
  • Dan Pu

摘要

Background

Although beneficial for patients through its minimally invasive nature, laparoscopic surgery creates unique training challenges due to limited instrument maneuverability, absence of stereovision, and inadequate real-time feedback. Traditional training models rely on subjective instructor evaluations, which are time-consuming and lack objective error detection. This study evaluates the efficacy of an Automated Error Detection System (AEDS), designed to provide real-time feedback on mistouch error counts, in improving laparoscopic skill acquisition compared to conventional methods.

Methods

Forty novice participants were recruited and randomized into Group A (AEDS-enhanced training) and Group B (traditional training). Group A underwent a crossover design: 10 min of baseline training without AEDS followed by 10 min with AEDS. Group B completed 20 min of traditional training. The training program encompassed standardized laparoscopic tasks designed to simulate real surgical procedures. Performance metrics, including task completion time and the number of errors made, were recorded for each participant through AEDS. Confidence levels were assessed through self-reported questionnaires. Furthermore, statistical analysis was performed to evaluate the effectiveness of AEDS. A paired t-test was utilized to assess error reductions within the AEDS group, and Bland-Altman analysis was used to analyze the self-estimate error bias. Also, a Wilcoxon signed-rank test evaluated improvements in confidence levels attributable to the system, while a Mann-Whitney U test was conducted to compare performance metrics between the AEDS and traditional training groups.

Results

Group A demonstrated a 24% reduction in errors post-AEDS (mean: 78.1 to 59.4, p < 0.001), outperforming Group B (mean: 67.4, p < 0.001). Participants significantly underestimated errors without AEDS (mean bias: +9.9 errors). Confidence levels in Group A increased from 2.4 to 3.6, significantly surpassing Group B’s improvement (median: 3) (p < 0.001). Real-time feedback bridged perceptual gaps, enhancing both technical precision and self-assessment accuracy.

Conclusion

The integration of AEDS into laparoscopic training significantly reduces operational errors, accelerates skill acquisition, and boosts trainee confidence by providing objective feedback. These findings advocate for adopting AEDS in surgical education to standardize training outcomes, mitigate overconfidence, and improve patient safety. Future studies should explore AEDS scalability across advanced procedural modules and diverse trainee cohorts.

Clinical trial number