Objective

There is currently a lack of in-depth comparative evaluation regarding the biomechanical properties of novel intramedullary nail devices in the treatment of basal femoral neck fractures (BFNF). This study aims to utilize finite element analysis to compare the performance differences of two novel devices with traditional PFNA and InterTan nails in the fixation of BFNF.

Methods

Based on a validated finite element model, this study constructed an accurate BFNF model and implanted four different intramedullary nail devices: PFNA, InterTan nail, PFBN (proximal femoral biomimetic nail), and NIS (novel intramedullary system). Under a vertical load of 2100N, the displacement and Von Mises stress (VMS) distribution of each group of models were evaluated through simulation testing.

Results

Under a load of 2100N, the PFBN device exhibited the best performance in terms of displacement and peak stress, while PFNA performed poorly. The peak displacement of the NIS device was lower than that of PFNA and InterTan nails, while the peak stress of the InterTan nail was lower than that of PFNA and NIS.

Conclusion

The PFBN device demonstrates stronger load-bearing and shear-resistant properties in the treatment of BFNF, and the NIS device also shows significant improvement in stability. Therefore, both the PFBN and NIS devices are reliable internal fixation techniques for the treatment of CFIFs, with potential clinical application prospects.