摘要

Purpose

To summarize and analyze the safety and efficacy of a Y-shape Sigma stent loaded with I125 in patients with inoperable malignant main airway obstruction.

Methods

This study was approved by the Institutional Ethics Committee, and a written informed consent was obtained from each participant. A Y-shape Sigma stent loaded with I125 was placed under vision from rigid bronchoscopy. The primary endpoint was alleviation of symptoms and improvement of Karnofsky Performance Status (KPS) score, and the secondary endpoint was complications and technical success.

Results

From November 2018 through June 2023, total 33 patients with malignant airway obstruction were palliatively treated by installing Y-shape Sigma stents loaded with I125. The airway lumen was immediately restored and the average airway opening significantly increased to 70 ± 9.4% after the procedure from baseline 30.2 ± 10.5% (p < 0.05). Average KPS score was improved from baseline 30.0 ± 10.0 to 70.0 ± 10.0 (p < 0.05) as well as PaO2 from baseline 50.1 ± 15.4 mmHg to 89.3 ± 8.6 mmHg (p < 0.05). The technical success rate of placing the stent in this study was 73%, and adverse events or complications including bleeding, I125 loss, and airway infection occurred during or after the procedure.

Conclusion

Placement of Y-shape Sigma stents under vision from rigid bronchoscopy in the patients with malignant airway obstruction is feasible and it immediately alleviates dyspnea and significantly improves quality of life.