Objective <p>To report the efficacy of “Xeno-ADM combined with inferior eyelid margin fixation” for entropion accompanied by lower eyelid retraction.</p> Methods <p>A retrospective review of 28 patients (48 eyes) diagnosed with lower eyelid entropion accompanied by lower eyelid retraction was performed. The follow-up period lasted more than 6&#xa0;months. MRD2, angle between the eyelashes and the corneal surface, ocular discomfort symptoms, and complications were recorded and used to evaluate the efficacy and safety.</p> Results <p>Twenty eight patients (48 eyes) were included, within 6&#xa0;months after surgery, 45 eyes (93.75%) had complete relief from ocular discomfort, while 3 eyes (6.3%) showed partial improvement; 48 eyes (100%) had complete resolution of the foreign body sensation; 15 eyes (83.3%) had complete relief from lacrimation, and 3 eyes (16.7%) showed partial improvement, MRD2 was from 7.2 (7.0, 7.5) mm to 5.5 (5.0, 5.5) mm (Z = -3.995, <i>P</i> &lt; 0.01). The angle between the eyelashes and the cornea was from 36.76 (32.18, 38.49) to 68.23 (67.30, 70.31) (Z = -6.031, <i>P</i> &lt; 0.01). And no other complications, such as infection, rejection, and dislocation, were observed.</p> Conclusion <p>Xeno-ADM combined with inferior eyelid margin fixation is reasonably successful in managing entropion accompanied by lower eyelid retraction.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Xeno-ADM combined with inferior eyelid margin fixation to treat entropion accompanied by lower eyelid retraction

  • Yangbin Fang,
  • Yao Lai,
  • Hongfei Liao,
  • Qin Huang

摘要

Objective

To report the efficacy of “Xeno-ADM combined with inferior eyelid margin fixation” for entropion accompanied by lower eyelid retraction.

Methods

A retrospective review of 28 patients (48 eyes) diagnosed with lower eyelid entropion accompanied by lower eyelid retraction was performed. The follow-up period lasted more than 6 months. MRD2, angle between the eyelashes and the corneal surface, ocular discomfort symptoms, and complications were recorded and used to evaluate the efficacy and safety.

Results

Twenty eight patients (48 eyes) were included, within 6 months after surgery, 45 eyes (93.75%) had complete relief from ocular discomfort, while 3 eyes (6.3%) showed partial improvement; 48 eyes (100%) had complete resolution of the foreign body sensation; 15 eyes (83.3%) had complete relief from lacrimation, and 3 eyes (16.7%) showed partial improvement, MRD2 was from 7.2 (7.0, 7.5) mm to 5.5 (5.0, 5.5) mm (Z = -3.995, P < 0.01). The angle between the eyelashes and the cornea was from 36.76 (32.18, 38.49) to 68.23 (67.30, 70.31) (Z = -6.031, P < 0.01). And no other complications, such as infection, rejection, and dislocation, were observed.

Conclusion

Xeno-ADM combined with inferior eyelid margin fixation is reasonably successful in managing entropion accompanied by lower eyelid retraction.