Objectives <p>To investigate the effect of adjunct micro-interventional pre-treatment for nucleus disassembly on the surgical efficiency of non-cavitating lensectomy during cataract surgery.</p> Methods and analysis <p>12 surgeons performed 512 consecutive cataract extractions using a sonic cavitation-free lensectomy with or without adjunct pre-treatment for nucleus disassembly. There were 2 interventional arms including (1) lensectomy without adjunct pre-treatment and (2) lensectomy with micro-interventional miLOOP pre-treatment.</p> Results <p>Successful lensectomy was achieved in all eyes using cavitation-free sonic lensectomy. Average baseline cataract density was 2.28 and 2.39 in the three groups, respectively. Compared to no pre-treatment, nucleus evacuation time was 24% (p = &lt; 0.001) faster with micro-interventional nucleus disassembly. Irrigation/aspiration (I/A) time was 14% faster with the micro-interventional pre-treatment (p = &lt; 0.001). Irrigation fluid use was 24% less with micro-interventional. There was a low rate of capsular tear of 1 case across 512 cases with no other unanticipated complications.</p> Conclusion <p>Micro-interventional pre-treatment for nucleus disassembly was associated with improved lensectomy time and fluidic efficiency compared to no pre-treatment. Non-cavitating lensectomy with the miCOR lens pen achieved effective fragmentation and extraction in all grades of cataract.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Micro-interventional pre-treatment for nucleus disassembly in the setting of non-cavitating sonic lensectomy: real-world evidence study in 512 cases

  • Sean Ianchulev,
  • Elizabeth Yeu,
  • Edward H. Hu,
  • Gautam Kamthan,
  • Seth Pantanelli,
  • Paul Singh,
  • Farrell Tyson

摘要

Objectives

To investigate the effect of adjunct micro-interventional pre-treatment for nucleus disassembly on the surgical efficiency of non-cavitating lensectomy during cataract surgery.

Methods and analysis

12 surgeons performed 512 consecutive cataract extractions using a sonic cavitation-free lensectomy with or without adjunct pre-treatment for nucleus disassembly. There were 2 interventional arms including (1) lensectomy without adjunct pre-treatment and (2) lensectomy with micro-interventional miLOOP pre-treatment.

Results

Successful lensectomy was achieved in all eyes using cavitation-free sonic lensectomy. Average baseline cataract density was 2.28 and 2.39 in the three groups, respectively. Compared to no pre-treatment, nucleus evacuation time was 24% (p = < 0.001) faster with micro-interventional nucleus disassembly. Irrigation/aspiration (I/A) time was 14% faster with the micro-interventional pre-treatment (p = < 0.001). Irrigation fluid use was 24% less with micro-interventional. There was a low rate of capsular tear of 1 case across 512 cases with no other unanticipated complications.

Conclusion

Micro-interventional pre-treatment for nucleus disassembly was associated with improved lensectomy time and fluidic efficiency compared to no pre-treatment. Non-cavitating lensectomy with the miCOR lens pen achieved effective fragmentation and extraction in all grades of cataract.