Iris neovascularization and neurotrophic keratopathy following ultrasound cycloplasty in refractory glaucoma: case series

  • Zidong Chen,
  • Yanyan Wu,
  • Minbin Yu

摘要

Background

Ultrasound cycloplasty is a noninvasive surgery used to reduce intraocular pressure in patients with glaucoma, with fewer severe complications. This report presents several cases of iris neovascularization and neurotrophic keratopathy following ultrasound cycloplasty.

Case presentation

Six patients diagnosed with refractory glaucoma underwent ultrasound cycloplasty at our clinic. Three cases developed iris neovascularization at postoperative day 3, week 2 and week 4 respectively, with intraocular pressure ranging from 12 to 24 mmHg. The other three cases developed neurotrophic keratopathy at postoperative week 3, week 6 and week 8 which completely healed within 60 days.

Conclusions

Iris neovascularization and neurotrophic keratopathy can be triggered after ultrasound cycloplasty, which are uncommon and self-limited but potentially vision-threatening. Preoperative risk assessment and regular postoperative follow-up are recommended to manage complications effectively.