Background <p>To evaluate the performance of a deep learning reconstruction (DLR) based on Adaptive-Compressed sensing (CS)-Network for brain MRI and validate it in a clinical setting.</p> Methods <p>Ten healthy volunteers and 22 consecutive patients were prospectively enrolled. Volunteers underwent 3D brain MRI including T1 without CS factor (9:16&#xa0;min, reference standard); with CS factor of 2 without DLR (CS2, 4:6&#xa0;min); with CS factor of 2 with DLR (DLR-CS2); with CS factor of 4 without DLR (CS4, 2:6&#xa0;min); and with CS factor of 4 with DLR (DLR-CS4). The patients’ MRI included the CS2 and DLR-CS4. The volumes of lateral ventricles, hippocampus, choroid plexus, and white matter hypointensity were calculated and compared among the sequences. Three radiologists independently assessed anatomical conspicuity, overall image quality, artifacts, signal-to-noise ratio (SNR), and sharpness using a 5-point scale for each sequence.</p> Results <p>Applying acceleration factors of 2 and 4 reduced the scan time to 65.4% and 33.5%, respectively, of that of the reference standard. Volumes of all the measured subregions showed no significant differences among different sequences in all participants. In qualitative analysis, the interrater agreement was excellent (κ = 0.844–0.926). In volunteers, quality of DLR-CS4 were comparable to those of CS2 for all metrics except for the overall image quality and SNR despite a 51.2% scan time reduction. In patients, DLR-CS4 showed quality comparable to that of CS2 for all metrics.</p> Conclusions <p>DLR allowed the scan time reduction by at least half without sacrificing image quality and volumetric quantification accuracy, supporting its reliability and efficiency.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Deep learning-based reconstruction for three-dimensional volumetric brain MRI: a qualitative and quantitative assessment

  • Yeseul Kang,
  • Sang-Young Kim,
  • Jun Hwee Kim,
  • Nak-Hoon Son,
  • Chae Jung Park

摘要

Background

To evaluate the performance of a deep learning reconstruction (DLR) based on Adaptive-Compressed sensing (CS)-Network for brain MRI and validate it in a clinical setting.

Methods

Ten healthy volunteers and 22 consecutive patients were prospectively enrolled. Volunteers underwent 3D brain MRI including T1 without CS factor (9:16 min, reference standard); with CS factor of 2 without DLR (CS2, 4:6 min); with CS factor of 2 with DLR (DLR-CS2); with CS factor of 4 without DLR (CS4, 2:6 min); and with CS factor of 4 with DLR (DLR-CS4). The patients’ MRI included the CS2 and DLR-CS4. The volumes of lateral ventricles, hippocampus, choroid plexus, and white matter hypointensity were calculated and compared among the sequences. Three radiologists independently assessed anatomical conspicuity, overall image quality, artifacts, signal-to-noise ratio (SNR), and sharpness using a 5-point scale for each sequence.

Results

Applying acceleration factors of 2 and 4 reduced the scan time to 65.4% and 33.5%, respectively, of that of the reference standard. Volumes of all the measured subregions showed no significant differences among different sequences in all participants. In qualitative analysis, the interrater agreement was excellent (κ = 0.844–0.926). In volunteers, quality of DLR-CS4 were comparable to those of CS2 for all metrics except for the overall image quality and SNR despite a 51.2% scan time reduction. In patients, DLR-CS4 showed quality comparable to that of CS2 for all metrics.

Conclusions

DLR allowed the scan time reduction by at least half without sacrificing image quality and volumetric quantification accuracy, supporting its reliability and efficiency.