Oxygen reserve index vs. peripheral oxygen saturation for the prediction of hypoxemia in morbidly obese patients: a prospective observational study

  • Kemal Tolga Saraçoğlu,
  • Gülten Arslan,
  • Ayten Saraçoğlu,
  • Özlem Sezen,
  • Paweł Ratajczyk,
  • Tomasz Gaszynski

摘要

Background

Pulse oximetry is a standart of anesthesia for perioperative monitoring. Due to the principles of Hb oxygen dissociation curve, peripheral oxygen saturation has an approximate sensitivity and specificity of 90% for the detection of hypoxemia.

Objectives

The primary outcome of the study was to evaluate ORi as an early parameter to determine hypoxia in morbidly obese patients. The secondary outcome was to compare the effectiveness of ORi with SpO2 in non-obese patients.

Design

Prospective, observational study.

Setting

Department of elective operating room at tertiary hospital.

Patients and methods

Observational study included written informed consent from 51 patients with 19 < BMI < 25 kg/m2 and 51 patients with BMI > 40 kg/m2 undergoing an elective surgery requiring tracheal intubation. In addition to standard monitors, an ORi sensor was placed and baseline values were recorded. The patients were preoxygenated until end tidal expiratory oxygen concentration is reached to 90%. After anesthesia induction and tracheal intubation, the breathing circuit was not connected tracheal tube until the SpO2 decreased to 95%. Shapiro-Wilk, Pearson Chi-square, t-test, and Mann Whitney U test were used for the study.

Main outcome measures

Times of tolerable apnea, ORi and SpO2 values at the end of preoxygenation, beginning of intubation, beginning of the ORi alarm, when SpO2 reached 95%, and when ORi reaches a plateau.

Sample size

102 patients.

Results

The alert period: time to reach ORi from 0.24 to a value of 95% SpO2 was observed as 32 s in morbidly obese patients and 94 s in patients with a normal body mass index. The SpO2 alert period was determined as time difference between 97% and 95% SpO2. The data were recorded as 15 s and 36 s, respectively. It was observed that tolerable apnea, ORi, SpO2 and added alert times were longer in patients with normal BMI compared to morbidly obese patients.

Conclusions

As a result, ORi can provide an early warning to prevent unexpected hypoxia before saturation begins to decrease in morbidly obese patients.

Limitations

Inability to perform arterial blood gas sampling in the time periods when we looked at the parameters to determine the relationship between ORi and PaO2.

Clinical trials. gov identifier

NCT05480748 registered 2022-07-29.