错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Assessing the efficacy of difficult airway alerts in electronic medical records: a quality improvement study

  • Wen-Shen Lee,
  • Luke R. Fletcher,
  • Shervin Tosif,
  • Timothy Makar,
  • Jon M. Graham

摘要

Study design

Retrospective analysis of difficult airway alerts in a major tertiary centre.

Objective

To investigate the completeness, utility and efficacy of difficult airway alerts and their impact on future airway management episodes.

Design, data sources and methods

Patients who had a “difficult airway” entry on electronic medical records (EMR) from 2011 to 2021 were included. Each alert was analyzed by a team of anesthetists with expertise in difficult airway management for its quality, appropriateness, and impact on future airway management episodes. Alert quality was defined as to whether the content of the alert contained pertinent information for emergent airway management. Alert appropriateness was defined as to whether the experts would be unhappy to perform a rapid sequence induction and intubation, if required, following review of all available documentation.

Results

141 patients were included for this study, with a mean age of 58.6 +/- 15.3 years. Ninety-three (66%) alerts were created by medical staff, of which 52 were recorded by consultant anesthetists. 117 alerts (83%) were deemed to be appropriate by the airway expert team, but only 40 alerts (28%) were found to have sufficient quality to be helpful in emergent airway management. Sixty-five patients (47%) had at least one subsequent airway management episode, of which 35 patients (56%) underwent a change of management following alert creation. We proceeded to modify 103 alerts (73%) to improve their quality to aid future encounters.

Conclusion

Difficult Airway encounters are an uncommon event in anesthesia, but clear, comprehensive and effectively communicated documentation is required to minimize the risk in future encounters. In our institution, while most difficult airway alerts were appropriate, we found significant heterogeneity in the quality of this documentation, which limits the clinical utility of the alert system. We have taken measures to improve local processes of difficult airway documentation and considered the implications of our project for the broader airway management community.

Trial registration

Not applicable.