<p>MALDI-TOF MS is an innovative tool for identifying hematophagous and non-hematophagous arthropods at various life stages. However, identification by MALDI-TOF MS currently requires euthanizing of the specimen, hindering further phenotypic tests. All arthropods have a common factor, molting of their exoskeletons leaving a remaining structure known as the exuviae. This phenomenon is indispensable for their growth and can evidence past arthropod presence. This study assessed the performance of MALDI-TOF MS biotyping for arthropod identification using exuviae from nine distinct laboratory-reared species (<i>Aedes aegypti</i>, <i>Anopheles coluzzii</i>, <i>Cimex lectularius</i>, <i>C. hemipterus</i>, <i>Pediculus humanus humanus</i>, <i>Triatoma infestans</i>, <i>Rhodnius prolixus</i>, <i>Supella longipalpa</i> and <i>Blattella germanica</i>) compared its efficiency with a molecular identification approach using DNA sequencing. Molecular analysis showed low DNA quantity in exuviae (<i>n</i> = 108) across species, resulting in low success of COI, 16s, and 18s amplification (50.0%), depending on the species and sequencing (10.2%). The establishment of an exuviae protocol for MS submission yielded spectra of high reproducibility and specificity per species. After upgrading a homemade reference MS database with exuviae spectra, a query with remaining spectra revealed that 100% of samples were correctly identified, with 85.8% (278/324) exceeding the threshold score value for reliable identification. MALDI-TOF MS showed high efficiency in identifying various arthropod species based on their exuviae. This approach is a groundbreaking development in the field of entomology underlining that MALDI-TOF outperformed traditional methods of exuviae identification, including morphological and molecular tools. It also prevents specimen sacrifice which could be used for complementary analyses.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Assessment of MALDI-TOF MS for Arthropod Identification Based on Exuviae Spectra Analysis

  • Rym Bouledroua,
  • Adama Zan Diarra,
  • Remy Amalvict,
  • Jean-Michel Berenger,
  • Ahmed Benakhla,
  • Philippe Parola,
  • Lionel Almeras

摘要

MALDI-TOF MS is an innovative tool for identifying hematophagous and non-hematophagous arthropods at various life stages. However, identification by MALDI-TOF MS currently requires euthanizing of the specimen, hindering further phenotypic tests. All arthropods have a common factor, molting of their exoskeletons leaving a remaining structure known as the exuviae. This phenomenon is indispensable for their growth and can evidence past arthropod presence. This study assessed the performance of MALDI-TOF MS biotyping for arthropod identification using exuviae from nine distinct laboratory-reared species (Aedes aegypti, Anopheles coluzzii, Cimex lectularius, C. hemipterus, Pediculus humanus humanus, Triatoma infestans, Rhodnius prolixus, Supella longipalpa and Blattella germanica) compared its efficiency with a molecular identification approach using DNA sequencing. Molecular analysis showed low DNA quantity in exuviae (n = 108) across species, resulting in low success of COI, 16s, and 18s amplification (50.0%), depending on the species and sequencing (10.2%). The establishment of an exuviae protocol for MS submission yielded spectra of high reproducibility and specificity per species. After upgrading a homemade reference MS database with exuviae spectra, a query with remaining spectra revealed that 100% of samples were correctly identified, with 85.8% (278/324) exceeding the threshold score value for reliable identification. MALDI-TOF MS showed high efficiency in identifying various arthropod species based on their exuviae. This approach is a groundbreaking development in the field of entomology underlining that MALDI-TOF outperformed traditional methods of exuviae identification, including morphological and molecular tools. It also prevents specimen sacrifice which could be used for complementary analyses.