Abstract <p>Parameterizations of signals from the towers of the electromagnetic calorimeter of the MPD/NICA detector, aimed at an estimation of the time resolution of the calorimeter, are considered. Optimal parameters of the timing are determined within the constant fraction method. In test measurements with cosmic rays, a time resolution of 1.3–0.8 ns was obtained depending on the signal amplitude. These results show the possibility of relative calibration of the time parameters of calorimeter towers using cosmic rays.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Parameterization of SiPM Signals of MPD/ECal for TOF Measurements

  • P. A. Bakhtin,
  • V. M. Baryshnikov,
  • S. A. Bulychjov,
  • G. E. Fomenko,
  • V. V. Kulikov,
  • A. A. Kulikovskaya,
  • M. A. Martemianov,
  • M. A. Matsyuk,
  • I. A. Tyapkin

摘要

Abstract

Parameterizations of signals from the towers of the electromagnetic calorimeter of the MPD/NICA detector, aimed at an estimation of the time resolution of the calorimeter, are considered. Optimal parameters of the timing are determined within the constant fraction method. In test measurements with cosmic rays, a time resolution of 1.3–0.8 ns was obtained depending on the signal amplitude. These results show the possibility of relative calibration of the time parameters of calorimeter towers using cosmic rays.