错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Developing the DECRIS-5M ECR Ion Source for the DC-140 Cyclotron Complex

  • D. K. Pugachev,
  • S. L. Bogomolov,
  • A. E. Bondarchenko,
  • K. I. Berestov,
  • K. I. Kuzmenkov,
  • V. N. Loginov,
  • A. N. Lebedev,
  • V. E. Mironov,
  • D. S. Podoinikov

摘要

Abstract

The DC-140 cyclotron complex now under construction at the Flerov Laboratory of Nuclear Reactions (FLNR) is designed for wide range of applied research using accelerated heavy ion beams, e.g., studying the radiation physics of solids, the development and production of track membranes (nuclear filters), and the radiation resistance of electronic components. To perform experiments, the accelerator must provide accelerated ion beams with two fixed energies: 2.1 MeV/nucleon and 4.8 MeV/nucleon in the mass range of Ne to Bi, with intensities of up to 1012 particles/s (for Xe ions) on the target. In accordance with the working diagram of DC-140 cyclotron, the ion source must provide ion beams with mass-to-charge ratios in the range A/Z = 5–8 (Ne4+–Bi38+).