Abstract <p>A highly sensitive electrochemical sensor was developed for the detection of the novel antihypertensive drug lercanidipine (LCP). Using zirconium oxychloride (ZrOCl<sub>2</sub>·8H<sub>2</sub>O) and graphene oxide (GO) as raw materials, polydiallyldimethylammonium chloride (PDDA) as the eco-friendly reducing agent, nano-zirconium dioxide/reduced GO/PDDA (ZrO<sub>2</sub>–rGO–PDDA) composite was prepared by hydrothermal synthesis with doped cerium chloride. Transmission electron microscopy, Fourier transform infrared spectrum, and electrochemical impedance spectroscopy were employed to characterize ZrO<sub>2</sub>–rGO–PDDA composite. The electrochemical behavior of LCP at ZrO<sub>2</sub>–rGO–PDDA modified glassy carbon electrode (ZrO<sub>2</sub>–rGO–PDDA/GCE) was studied by voltammetry. Under optimized measurement conditions, the linear plot between the peak current of LCP and its concentration was found within the range of 4.00 × 10<sup>–7</sup>–1.58 × 10<sup>–4</sup> mol/L, with a detection limit of 8.26 × 10<sup>–8</sup> mol/L. This new sensor was employed successfully to determine the content of LCP drug on the market. The spiked recovery experiments showed that the recoveries of LCP ranged from 97.78 to 101.04%. The developed sensor exhibits high sensitivity and accuracy for the determination of LCP.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

A Sensitive Electrochemical Sensor Based on Nano-Zirconium Dioxide/Reduced Graphene Oxide Modified Electrode for Lercanidipine Determination

  • Yingliang Wei,
  • Anting Wang,
  • Xiaoru Ren,
  • Chunlai Wu,
  • Fang Wang

摘要

Abstract

A highly sensitive electrochemical sensor was developed for the detection of the novel antihypertensive drug lercanidipine (LCP). Using zirconium oxychloride (ZrOCl2·8H2O) and graphene oxide (GO) as raw materials, polydiallyldimethylammonium chloride (PDDA) as the eco-friendly reducing agent, nano-zirconium dioxide/reduced GO/PDDA (ZrO2–rGO–PDDA) composite was prepared by hydrothermal synthesis with doped cerium chloride. Transmission electron microscopy, Fourier transform infrared spectrum, and electrochemical impedance spectroscopy were employed to characterize ZrO2–rGO–PDDA composite. The electrochemical behavior of LCP at ZrO2–rGO–PDDA modified glassy carbon electrode (ZrO2–rGO–PDDA/GCE) was studied by voltammetry. Under optimized measurement conditions, the linear plot between the peak current of LCP and its concentration was found within the range of 4.00 × 10–7–1.58 × 10–4 mol/L, with a detection limit of 8.26 × 10–8 mol/L. This new sensor was employed successfully to determine the content of LCP drug on the market. The spiked recovery experiments showed that the recoveries of LCP ranged from 97.78 to 101.04%. The developed sensor exhibits high sensitivity and accuracy for the determination of LCP.