<p>This paper presents the results of a study into the cooling efficiency of a target in a test section using a water-air spray under high heat flux conditions that is applicable to solving temperature control problems in the fusion energy, microelectronic, and metallurgical industries. Experimental studies were conducted in the ‘One-Sided Target Heating’ thermophysical test facility at the National Research University “Moscow Power Engineering Institute” (MPEI). In the experiments, the flowrates of the coolant components ranged from 0.5 to 2 l/min for water and from 2 to 100 l/min for air. It is found that this cooling system can remove heat loads as high as 10 MW/m<sup>2</sup> from the target at relatively low pressures of the coolant components. The study demonstrates that the examined cooling method can yield heat transfer coefficients of up to 150 kW/(m<sup>2</sup>·K).</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Experimental study of heat transfer during cooling of a high-temperature surface by a water-air spray

  • A. Zakharenkov,
  • A. Demidov,
  • A. Dedov,
  • A. Komov

摘要

This paper presents the results of a study into the cooling efficiency of a target in a test section using a water-air spray under high heat flux conditions that is applicable to solving temperature control problems in the fusion energy, microelectronic, and metallurgical industries. Experimental studies were conducted in the ‘One-Sided Target Heating’ thermophysical test facility at the National Research University “Moscow Power Engineering Institute” (MPEI). In the experiments, the flowrates of the coolant components ranged from 0.5 to 2 l/min for water and from 2 to 100 l/min for air. It is found that this cooling system can remove heat loads as high as 10 MW/m2 from the target at relatively low pressures of the coolant components. The study demonstrates that the examined cooling method can yield heat transfer coefficients of up to 150 kW/(m2·K).