<p>Cardiotocography (CTG) has a high false positive rate for the detection of babies at risk of birth asphyxia. Transabdominal Fetal Pulse Oximetry (TFO) has the potential to supplement CTG by enabling non-invasive measurement of fetal arterial blood oxygen saturation (fSpO<sub>2</sub>). Previous attempts at TFO were limited to intermittent measurements using highly specialized and precise instruments. We present a TFO system, utilizing multiple commodity silicon photo-detectors to acquire mixed maternal-fetal PPG signals, for non-invasive and continuous detection of fetal instantaneous normoxia vs. hypoxemia status, relative to a user-specified threshold. Data from controlled de-saturation experiments using pregnant ewes with an in-utero hypoxic lamb model, from a total of <i>n</i> = 8 hypoxic rounds (length = 34.5 ± 12 min), is used to validate the technology. The multi-layer perceptron model is used for information fusion, and fetal arterial blood oxygen saturation obtained from blood gas analysis is used as a gold standard. The method detects instantaneous hypoxemia (fSpO<sub>2</sub> &lt;30%) with 87.6% accuracy. Cross-validation shows an average sensitivity of 88.2% and specificity of 71.2%. The receiver operating characteristic (ROC) curves showed strong discrimination abilities in all cross-validation iterations (AUC = 0.87). This study underscores TFO’s promise for accurate detection of instantaneous fetal hypoxemia relative to a user-defined threshold value, and for contribution to enhancement of intrapartum fetal monitoring in the longer term.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Non-invasive detection of instantaneous fetal hypoxemia in large animal model of pregnancy

  • Weitai Qian,
  • Mahya Saffarpour,
  • Rishad R. Joarder,
  • Begum Kasap,
  • Kourosh Vali,
  • Tailai Lihe,
  • Herman L. Hedriana,
  • Aijun Wang,
  • Diana Farmer,
  • Soheil Ghiasi

摘要

Cardiotocography (CTG) has a high false positive rate for the detection of babies at risk of birth asphyxia. Transabdominal Fetal Pulse Oximetry (TFO) has the potential to supplement CTG by enabling non-invasive measurement of fetal arterial blood oxygen saturation (fSpO2). Previous attempts at TFO were limited to intermittent measurements using highly specialized and precise instruments. We present a TFO system, utilizing multiple commodity silicon photo-detectors to acquire mixed maternal-fetal PPG signals, for non-invasive and continuous detection of fetal instantaneous normoxia vs. hypoxemia status, relative to a user-specified threshold. Data from controlled de-saturation experiments using pregnant ewes with an in-utero hypoxic lamb model, from a total of n = 8 hypoxic rounds (length = 34.5 ± 12 min), is used to validate the technology. The multi-layer perceptron model is used for information fusion, and fetal arterial blood oxygen saturation obtained from blood gas analysis is used as a gold standard. The method detects instantaneous hypoxemia (fSpO2 <30%) with 87.6% accuracy. Cross-validation shows an average sensitivity of 88.2% and specificity of 71.2%. The receiver operating characteristic (ROC) curves showed strong discrimination abilities in all cross-validation iterations (AUC = 0.87). This study underscores TFO’s promise for accurate detection of instantaneous fetal hypoxemia relative to a user-defined threshold value, and for contribution to enhancement of intrapartum fetal monitoring in the longer term.