<p>In PET systems, the SNR relies on the coincidence time resolution (CTR) of 511&#xa0;keV photon pairs. This research investigates the impact of reflectors, surface treatments, materials, and scintillation crystal length on the CTR of a brainPET detector using dual-layer offset scintillators (DLOs). This study is based on a brainPET, under development at the University of Manitoba, to propose a new design to achieve an improved CTR. Four different pairs of LYSO crystals with distinct optical compositions, surface treatments, and reflective materials were simulated (using GATEv9.3). Each model comprises two LYSO crystal with dimensions of 3 × 3  × 10 mm<sup>3</sup>. Considering the initial experimental data from the brainPET lab, simulation results showed that the crystal with a roughened surface and ESR reflector demonstrated 13.6% energy resolution and an average 17.8% improvement in CTR compared to other models. In addition, a more comprehensive model, including a dual-layer offset detector was designed. The bottom and top layers have 25 × 19 and 24 × 18 crystals with thickness of 12 and 8&#xa0;mm, respectively in the DLO model. The simulation investigation showed that the DLO configuration could enhance the time resolution by 17.5% and the energy resolution by 5.4% which are considerably comparable to the state-of-the-art brainPET systems.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

A new design to improve time resolution in a time of flight brain PET using dual layer offset scintillator crystals

  • Amir Beheshti,
  • Alireza Karimian,
  • Hossein Arabi,
  • Andrew. L. Goertzen

摘要

In PET systems, the SNR relies on the coincidence time resolution (CTR) of 511 keV photon pairs. This research investigates the impact of reflectors, surface treatments, materials, and scintillation crystal length on the CTR of a brainPET detector using dual-layer offset scintillators (DLOs). This study is based on a brainPET, under development at the University of Manitoba, to propose a new design to achieve an improved CTR. Four different pairs of LYSO crystals with distinct optical compositions, surface treatments, and reflective materials were simulated (using GATEv9.3). Each model comprises two LYSO crystal with dimensions of 3 × 3  × 10 mm3. Considering the initial experimental data from the brainPET lab, simulation results showed that the crystal with a roughened surface and ESR reflector demonstrated 13.6% energy resolution and an average 17.8% improvement in CTR compared to other models. In addition, a more comprehensive model, including a dual-layer offset detector was designed. The bottom and top layers have 25 × 19 and 24 × 18 crystals with thickness of 12 and 8 mm, respectively in the DLO model. The simulation investigation showed that the DLO configuration could enhance the time resolution by 17.5% and the energy resolution by 5.4% which are considerably comparable to the state-of-the-art brainPET systems.