<p>All key thermoelectric properties of thermoelectric materials (i.e., resistivity ρ, dimensionless figure of merit <i>zT</i>, thermal conductivity κ<sub><i>TE</i></sub>, and Seebeck coefficient <i>S</i>) were measured at 300&#xa0;K using time-domain impedance spectroscopy (TDIS). This method accounted for heat leakage through lead wires connected to a bismuth–telluride-based Π-shaped thermoelectric module. The values of ρ and <i>zT</i>, without considering heat leakage, were rapidly determined in the frequency domain using impedance measurements with alternating current and in the time domain through transient-response measurements with direct current. The thermal conductance ratio <i>K</i><sub><i>lead</i></sub>/<i>K</i><sub><i>TE</i></sub>, which represents the relationship between the thermal conductance of the thermoelectric material <i>K</i><sub><i>TE</i></sub> and that of the lead wires causing heat leakage <i>K</i><sub><i>lead</i></sub>, was also evaluated. The effective dimensionless figure of merit <i>zT</i><sub><i>eff</i></sub> was estimated at various <i>K</i><sub><i>lead</i></sub>/<i>K</i><sub><i>TE</i></sub> ratios to assess the influence of heat leakage. At 300&#xa0;K, the estimated thermoelectric parameters were ρ = 10.19&#xa0;μΩm, <i>zT</i> = 0.8645 ± 0.0003, κ<sub><i>TE</i></sub> = 1.259 ± 0.003 W/mK, and |<i>S</i>|&#xa0;= 192.3 ± 0.4&#xa0;μV/K. The results indicate that for accurate determination of all thermoelectric parameters using TDIS, the condition <i>K</i><sub><i>lead</i></sub>/<i>K</i><sub><i>TE</i></sub> &gt; 0.1 is required when performing <i>K</i><sub><i>lead</i></sub>/<i>K</i><sub><i>TE</i></sub>-dependent experiments on the modules with <i>zT</i> = 0.8645.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Measuring thermoelectric module properties by time-domain impedance spectroscopy using heat leakage at 300 K

  • Kotoko Kodama,
  • Yasuhiro Hasegawa

摘要

All key thermoelectric properties of thermoelectric materials (i.e., resistivity ρ, dimensionless figure of merit zT, thermal conductivity κTE, and Seebeck coefficient S) were measured at 300 K using time-domain impedance spectroscopy (TDIS). This method accounted for heat leakage through lead wires connected to a bismuth–telluride-based Π-shaped thermoelectric module. The values of ρ and zT, without considering heat leakage, were rapidly determined in the frequency domain using impedance measurements with alternating current and in the time domain through transient-response measurements with direct current. The thermal conductance ratio Klead/KTE, which represents the relationship between the thermal conductance of the thermoelectric material KTE and that of the lead wires causing heat leakage Klead, was also evaluated. The effective dimensionless figure of merit zTeff was estimated at various Klead/KTE ratios to assess the influence of heat leakage. At 300 K, the estimated thermoelectric parameters were ρ = 10.19 μΩm, zT = 0.8645 ± 0.0003, κTE = 1.259 ± 0.003 W/mK, and |S| = 192.3 ± 0.4 μV/K. The results indicate that for accurate determination of all thermoelectric parameters using TDIS, the condition Klead/KTE > 0.1 is required when performing Klead/KTE-dependent experiments on the modules with zT = 0.8645.